Performance Data Sheet
SmartWater Filtration S stem-GE
This s stem has been tested and certified in filter model GE MWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the s stem was reduced to a concentration less than or equal to the permissible limit for water
leaving the s stem, as specified in NSF/ANSI Standards 42 and 53.* (Safet factors built in for unmetered usage)
Standard No. 42: Aesthetic effects
Substance
Reduction
Average Influent
Chlorine Taste
2.0 mg/L
& Odor
Nominal Particulate
7,833,333 pts/mL At least 10,000 particles/mL 99.7%
Class I, ≥0.5 to <1.0 μm
Standard No. 53: Health effects
Substance
Reduction
Average Influent
Cyst*
147,5000 cysts/L Minimum 50,000 cysts/L
Asbestos
47 MF/L
Atrazine
0.009 mg/L
Benzene
0.016 mg/L
Carbofuran
0.08 mg/L
Endrin
0.006 mg/L
Lead @ pH 6.5
0.152 mg/L
Lead @ pH 8.5
0.148 mg/L
Lindane
0.002 mg/L
Mercury @ pH 6.5
0.0058 mg/L
Mercury @ pH 8.5
0.0061 mg/L
P-Dichlorobenzene
0.222 mg/L
Tetrachloroethylene
0.015 mg/L
Toxaphene
0.015 mg/L
2, 4-D
0.218 mg/L
*Based on the use of Cryptosporidium parvum oocysts
Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSF testing.
Application Guidelines/Water Supply Parameters
Service Flow
0.5 gpm (1.9 lpm)
Water Supply
Potable Water
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Operating Specifications
Pressure quirement: 40–1
ps .8–8.2 bar) non-shock
Temperatur 33–100°F
–38°C)
Flow
gp
lpm)
General Installation/Operation/Maintenance Requirements
trappe air.
expected
drop belo 33°F °C). Do no instal s stem in area wher
ambien
mperatures ma go abov 100º or belo 40°F Do no instal
on ho wate
ppl .
Special Notices
Installation instructions ar included with th produc when shipped.
This drinking wate s stem must be aintained accordin
instructions includin
placemen
Do no us with wate that is microbiologicall unsa or
withou adequate disinfection befo or af
c st duction ma be used on disinfecte wate that ma
Te
Standard No. 42: Aesthetic Effects
Chemical
Ta
GE
geapplianceparts.com
44
NSF Specified Challenge
Average %
Concentration
Reduction
2.0mg/L ± 10%
97.5%
NSF Specified Challenge
Average %
Concentration
Reduction
99.99%
10
7
to 10
8
fibers/L; fibers
>99%
greater than 10 μm in length
0.009 mg/L ± 10%
94.5%
0.015 mg/L ± 10%
96.7%
0.08 mg/L ± 10%
98.7%
0.006 mg/L ± 10%
95.6%
0.15 mg/L ± 10%
99.3%
0.15 mg/L ± 10%
99.3%
0.002 mg/L ± 10%
99%
0.006 mg/L ± 10%
93.2%
0.006 mg/L ± 10%
93.2%
0.225 mg/L ± 10%
99.7%
0.015 mg/L ± 10%
96.6%
0.015 mg/L ± 10%
93.2%
0.210 mg/L ± 10%
99.5%
manufacturer's
filte
r
unknow qualit
th s stem
stem
rtified
rd
rt
I
®
MWF Cartridge
Average Product
Max Permissible Product
Water Concentration
Water Concentration
0.05 mg/L
N/A
18,617 pts/mL
N/A
Average Product
Max Permissible Product
Water Concentration
Water Concentration
1 cyst/L
N/A
<1 MF/L
N/A
0.0005 mg/L
0.003 mg/L
0.0005 mg/L
0.005 mg/L
0.001 mg/L
0.04 mg/L
0.0003 mg/L
0.002 mg/L
0.001 mg/L
0.010 mg/L
0.001 mg/L
0.010 mg/L
0.00002 mg/L
0.0002 mg/L
0.0004 mg/L
0.002 mg/L
0.0004 mg/L
0.002 mg/L
0.005 mg/L
0.075 mg/L
0.0005 mg/L
0.005 mg/L
0.001 mg/L
0.003 mg/L
0.0009 mg/L
0.07 mg/L
Water Pressure
Water Temperature
Th
ntaminants or he subs
treatmen s stem ar no necessaril in
Chec
mpliance wit th applicable stat an lo
that whil th
stin wa performe unde standard laborator
ac
rformanc ma
accordance with manufacturer recommende procedures an guidelines
Installation an us
instal if wate pressu exceeds
52
ould instal
professional if
ar uncertai ho
Do no install wher wate hammer
conditions exis
must instal
professional if
ar uncertai ho
controlling pressu du
c sts.
re
:
Standard No. 53: Health Effects
n
ro
NSF Reduction
Requirements
≥50%
≥85%
NSF Reduction
Requirements
≥99.95%
≥99%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
40–120 psi (2.8–8.2 bar)
33ºF–100ºF (0.6ºC–38ºC)
or duced b this wate
ur water.
laws an
r
stem must be installed an operated in
mpl wit al stat an lo
plumbin
psi.
ur wate pressu exceeds 80 ps
pressure-limitin
lve. Contac
plumbing
ec
ur wate pressure.
nditions ma occur. wate hammer
wate ammer arrester Contac
ec
this ondition.
therma expansio must be installed.
rc
To
n
NSF Test
Report
J-00077703
J-00077704
NSF Test
Report
J-00077721
J-00077707
J-00077708
J-00077717
J-00077718
J-00082185
J-00077722
J-00077723
J-00077726
J-00077727
J-00077728
J-00077729
J-00082184
J-00077730
J-00077705
gulations.
nditions
des. Do no
plumbin
n
REPLACEMENT
ELEMENT
PC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pzs23ksess

Table of Contents