Cleaning instructions

To ensure optimal performance of the unit,
cleaning has to be carried out at regular
intervals. Dirty unit may cause malfunction
and you may see error code "H99". Please
consult authorised dealer.
• Switch off the power supply and unplug before
cleaning.
• Do not touch the aluminium fi n, sharp parts may
cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap (
detergent.
• Do not use water hotter than 40 °C.
Indoor unit
Wipe the unit gently with a soft,
dry cloth.
Front panel
Wash gently and dry.
Remove the front panel
1 Raise
2 Slide to the right or left
3 Pull out the panel
Close it securely
2 Close down
3 Press both ends of the front panel
14
pH 7) or neutral household
For both sides
3
1
Insert at both sides
Indoor unit
Front panel
Air fi lters
Every 2 weeks
• Wash/rinse the fi lters gently
with water to avoid damage to
the fi lter surface.
• Dry the fi lters thoroughly under shade, away
from fi re or direct sunlight.
• Replace any damaged fi lters.
Remove air fi lter
2
For seasonal inspection after extended
non-use
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• Use Auto OFF/ON button to select COOL
operation. After 15 minutes of operation, it
is normal to have the following temperature
difference between air inlet and air outlet
vents:
COOL: ≥ 8 °C
For extended non-use
• Turn off the power supply and unplug.
• Remove the remote control batteries.
Aluminium fi n
Air fi lters
Attach air fi lter
Insert into the unit

Advertisement