DC Inverter U-match Series Duct Type Unit
⑤. Noise reduction and shock absorption shall be considered in air duct design
and construction. Moreover, the noise source shall avoid the crowd, e.g. the
return air inlet shall never be designed at the top of the user (office and rest
area).

3.3 Electrical Installation

3.3.1 Requirement and Notice on Electrical Installation
:
WARNING
The electrical installation for the air conditioner should observe the following
requirements:
①. The electrical installation must be conducted by professionals in compliance
with local laws and regulations and the instructions in this manual. Never
extend the power cord. The electric circuit must be equipped with a circuit
breaker and air switch both with sufficient capacity.
②. The unit's operating power must be within the nominal range stated in the
instruction manual. Use a specialized power circuit for the air conditioner. Do
not draw power from another power circuit.
③. The air conditioner circuit should be at least 1.5m away from any inflammable
surface.
④. The external power cord, connection wire of indoor and outdoor units and the
communication cords must be effectively fixed.
⑤. The external power cord, connection wire of indoor and outdoor units and the
communication cords can't directly contact any hot objects. For example: they
must not contact chimney pipes, warm gas pipes or other hot objects.
⑥. The external power cord, communication cords, and the connection wire of
indoor and outdoor units must not be squeezed. Never pull, stretch or bend the
wires.
⑦. The external power cord, communication cords and the connection wire of
indoor and outdoor units must not collide with any metal beam or edge on the
ceiling, or touch any metal burrs or sharp metal edge around.