Download Print this page
Intermatic INTT40404R Installation, Operation & Service Manual

Intermatic INTT40404R Installation, Operation & Service Manual

Pool/spa equipment controls, control panel with time switch for indoor/outdoor use, suitable for pool equipment control and for direct connection of underwater lights

Advertisement

Quick Links

WIRING DIAGRAM
Typical 120 Volt Installation
Filter and Cleaner Timer Inter-Connections
NOTES:
1. Grounding connections are not shown but must be provided. Refer to the National Electrical Code for details.
2. Diagrams above are only two of the many variations this Panel can accommodate.
LIMITED ONE YEAR WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace
it, at its sole option, the unit free of charge. This warranty applies only to the original purchaser and is not transferable. This warranty does not apply
to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unautho-
rized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the
product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal
rights and you may have other rights that vary from state to state.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER
EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE
OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product,
along with proof of purchase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After
Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000 http://www/intermatic.com Please be sure to wrap the product
securely when mailing to avoid shipping damage.
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
INTERMATIC INCORPORATED, SPRING GROVE, IL 60081-9698
http://www.intermatic.com
158TP10445
Typical 240 Volt Installation
4
T40000R SERIES
POOL/SPA EQUIPMENT CONTROLS
C C O O N N T T R R O O L L P P A A N N E E L L W W I I T T H H T T I I M M E E S S W W I I T T C C H H F F O O R R I I N N D D O O O O R R / / O O U U T T D D O O O O R R U U S S E E
Suitable for Pool Equipment Control and for Direct Connection of Underwater Lights
ELECTRICAL RATINGS: See inside Enclosure Door
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
Many of today's energy efficient pools and spas
utilize the advantages of a single electrical panel,
containing all the necessary controls for the safe,
efficient and automatic operation of the pool/spa
equipment. In addition, this Panel can also be
used to control any outdoor equipment, sign or
pump within its rated capacity.
The all-weather enclosure contains none one or
two heavy-duty, industrial grade Time Switches.
Also, it has provisions to install switches or a
GFCI receptacle on the side as well as the inside.
The Time Switch can also accommodate an
optional heater control (fireman) switch.
The Control is designed to operate any pump,
within its rated capacity. However, if protection
to prevent dry start is required by the pump
manufacturer, it must be provided in addition
to this Control. Contact pump manufacturer
if not sure and/or for more details.
INSTALLATION
OPERATION &
SERVICE MANUAL
1

Advertisement

loading

Summary of Contents for Intermatic INTT40404R

  • Page 1 Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS OPERATION When installing and operating this Product and other associated equipment, basic safety precautions should always be followed, TO SET FILTER PUMP TIME SWITCH, follow TIME SWITCH OPERATING including the following: instructions on the right. The length of the daily filtration/ INSTRUCTIONS 1.

This manual is also suitable for:

T40000r series