3. Invert the plastic regulator stem to achieve the
configuration "B" for Propane Gas and screw it in
tightly.
4. Screw the regulator stem and cap into place.
NOTE:
When converting for Propane Gas use, the pres-
sure supplied to the regulator must be between 11"
and 13" of the water column.
Replacing the burner nozzles
1. Remove the cooktop grates.
2. Remove the burner cover (1), the flame-spreader
crown (2) and the burner skirt (3) from the burner
base (4).
3. Remove the tightening screws (5), the cover
plate (6) and the gasket (7).
4. Remove the internal (8) and external (9) nozzles
and replace them with the LPG nozzles (see
"LPG nozzles table (Pressure in W.C.P.: 10")").
CAUTION
This procedure must be performed
for every burner.
5. Refit the burner components following the above
instructions in reverse.
Correct burners placement
Pay attention to place the burners in their correct
zones prior to remounting them
1. 18000 BTU brass coated burners - to be placed
in the front left and front right zones.
2. 12000 BTU black coated burners - to be placed
in all the other zones.