I. Startup
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
• If the appliance is turned off, wait for at least 3 minutes before restarting the
appliance to prevent damage to the compressor.
• To prevent damage to the water pump, do not leave the control switch in the
"WASH" position when the water tank is empty.
• At startup, confirm that all internal and external connections are free of leaks.
• The remote condensing unit must have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
1) Open the water supply line shut-off valve.
2) Remove the front panel.
3) Move the control switch to the "ICE" position.
4) Replace the front panel in its correct position.
5) Turn on the power supply, and allow the icemaker to operate for a total of 10 minutes.
6) Turn off the power supply, then remove the front panel.
7) Remove the insulation panel. Remove cube guide B, then remove cube guide A. See
Fig. 13. Remove the overflow cap, overflow pipe, and water shield.
8) Remove the drain plug. Allow the water tank to drain, then replace the drain plug in its
correct position. Be careful not to cross thread it.
9) Replace the water shield, overflow pipe, overflow cap, cube guide A, cube guide B, and
insulation panel in their correct positions. Be careful not to cross thread the overflow
pipe.
10) Clean the dispenser unit/storage bin liner
using a neutral cleaner. Rinse thoroughly
after cleaning.
11) Turn on the power supply to start the
automatic icemaking process.
12) To confirm bin control operation, press
and hold the bin control's actuator paddle
during the first 5 minutes of the freeze
cycle. The icemaker should shut down in
approximately 15 seconds.
13) Replace the front panel in its correct
position.
WARNING
NOTICE
Overflow Cap
Overflow Pipe
Fig. 13
Cube Guide A
24
Drain
Water
Shield
Plug
Cube Guide B