DeWalt XR LI-ION DCS7485N Original Instructions Manual page 18

Hide thumbs Also See for XR LI-ION DCS7485N:
Table of Contents

Advertisement

English
before installing and removing accessories, before
adjusting or changing set-ups or when making
repairs. Be sure the trigger switch is in the OFF position.
An accidental start-up can cause injury.

WARNING: The teeth of a new blade are very sharp and
can be dangerous.

WARNING: The saw blade MUST be replaced as described
in this section. ONLY use saw blades as specified under
Technical Data. We suggest DT99565. NEVER fit other
saw blades.
nOTE: This tool has blade installed from factory.(only for KR)
1. Raise the saw blade arbor to its maximum height by turning
the blade height adjustment wheel 
2. Remove the throat plate 
Throat Plate.
3. Using wrenches 
 21 
, loosen and remove the arbor nut 
and clamp washer 
 27 
clockwise.
4. Place the saw blade on to the arbor 
teeth of the blade 
 2 
point down at the front of the table.
Assemble the washers and arbor nut to the spindle and
tighten arbor nut 
 26 
as far as possible by hand, making
sure that the saw blade is against the inner washer and the
outer clamp washer 
 27 
largest diameter of the flange is against the blade. Ensure
the spindle and washers are free from dust and debris.
5. To keep the spindle from rotating when tightening the
arbor nut, use the open end of the blade wrench 
secure the spindle.
6. Using the closed end of the blade wrench, tighten the arbor
nut 
 26 
by turning it clockwise.
7. Replace the throat plate.

WARNING: Always check the rip fence pointer and the
blade guard assembly after having changed the blade.
Mounting/Removing the Blade Guard
Assembly(Fig. A, D)

WARNING: Use the guard assembly for all
through cutting.
1. Set the saw blade 
 2 
to the maximum cutting depth. Set it
at 45º and lock it.
2. Dismount the splitter screws 
3. Put the splitter 
 51 
on mounting block 
splitter plate 
 56 
.
4. Lock them by tightening the two screws 
5. Mount the blade guard assembly 
adjust it with the butterfly nut.

WARNING: Before connecting the table saw to the power
source or operating the saw, always inspect the blade
guard assembly for proper alignment and clearance
with saw blade. Check alignment after each change of
bevel angle.
16
 6 
 clockwise.
 17 
. Refer to Mounting the
from the saw arbor by turning anti-
 28 
making sure the
is against the blade. Ensure the
 21 
 52 
and splitter plate 
 53 
and add the
 52 
.
 11 
on the splitter 

WARNING: To reduce the risk of serious personal injury,
DO NOT operate saw if blade assembly is not securely
clamped in place.
When properly aligned, the splitter 
blade at both table top level, and at the top of the blade. Using
a straight edge, ensure that the blade 
splitter
 51 
. With power disconnected, operate the blade tilt and
height adjustments through the extremes of travel and insure
the blade guard assembly clears the blade in all operations.
Refer to Aligning Guard Assembly/Splitter to Blade.

WARNING: Correct mounting and alignment of the blade
guard assembly is essential to safe operation!
To Remove the Splitter/Blade Guard Assembly
(Fig. D)
1. Loosen the butterfly nut and remove the blade guard
 26 
assembly 
2. Dismount the splitter screws
3. Remove the splitter plate 
Anti-Kickback Assembly (Fig. S)

WARNING: To reduce the risk of serious personal injury,
the anti-kickback assembly must be in place for all
possible cuts.
1. Remove the anti-kickback assembly 
position by depressing the stem. Refer to Storage.
2. Locate the anti-kickback mounting slot 
of the blade guard assembly
to
3. Align the stem
stem and push down on the anti-kickback assembly
until it snaps and locks into place.
4. To remove the anti-kickback assembly, depress the stem
and pull up and out of the mounting slot.
With battery removed, operate the blade tilt and height
adjustments through the extremes of travel and ensure the
blade guard assembly clears the blade in all operations and that
the anti-kickback assembly is functioning.
Mounting the Throat Plate (Fig. E)
1. Align the throat plate 
the tabs on the back of the throat plate into the holes on the
back of the table opening.
2. Turn the locking screw 
 56 
.
to lock the table insert in place.
3. The throat plate includes four adjustment screws which
raise or lower the throat plate. When properly adjusted, the
front of the throat plate should be flush or slightly below the
 51 
and
surface of the table top and secured in place. The rear of the
throat plate should be flush or slightly above the table top.

WARNING: Never use the machine without the throat
plate. Immediately replace the throatplate when worn
or damaged.
Removing the Throat Plate
1. Remove the throat plate 
screw 
 30 
 51 
will be in line with the
 2 
 11 
from splitter
 51 
.
 52 
.
 54 
and splitter
 11 
 .
 57 
with the mounting slot. Depress the
 17 
as shown in Figure E, and insert
 30 
with a screw driver clockwise 90°
 17 
by turning the locking
with a screw driver 90˚ anti-clockwise
is aligned with the
 51 
.
 55 
  from the storage
 56 
at the top rear
 55 

Advertisement