GL300W External Battery Kit User Manual
Figure 10: Toggle Switches

3.3.1. SW101

SW101 is used to enable/disable the onboard motion sensor.

3.3.2. SW102

SW102 is used to configure the auto power up function. If it is set to 'L', the power output will be
enabled for at least 5 minutes every day even when the PCU is in rest. If SW102 is set to 'H', the
power output will never be enabled when the PCU is in rest. (In case the logical status of two
digital inputs are all 0).
There are some reporting messages relate to this function. Please refer to chapter 6.2.4 for
details.

3.3.3. SW103

SW103 is used to configure the logical status of digital input 1.

3.3.4. SW104

SW104 is used to enable/disable the indication LED. If SW104 is set to 'H', the LED will be
disabled. If SW104 is set to 'L', the LED will be enabled.
Please notice that even when the LED is enabled, it will only light when the power output is
enabled.