Grounding Appliance; Minimum Clearance To Combustibles; Minimum Mantel Clearances - Napoleon Stylus NEFP32-5320BW Installation And Operation Manual

Wallmount
Hide thumbs Also See for Stylus NEFP32-5320BW:
Table of Contents

Advertisement

Available languages

Available languages

installation
EN
2.2

grounding appliance

This appliance is for use on 120 volts. The cord has a plug as shown in (A). An adapter as shown in (C) is available
for connecting three-blade grounding type plugs to two-slot receptacles, as shown in (B).
The green grounding plug extending from the adapter must be connected to a permanent ground such as a
properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove plug from outlet.
(A)
note:
The appliance must be connected to a dedicated 15 amp circuit. The use of an extension cord is NOT
permitted.
2.3

minimum clearance to combustibles

2.4

minimum mantel clearances

!
WARNING
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
2" (51mm)
Side View (Wall Mount)
10
W415-1900 / E / 02.07.20
Grounding Methods
Metal Screw
Cover of
grounded
outlet box
(B)
Grounding Pin
Clearance to Combustibles
Combustibles to top
Combustibles to bottom
Combustibles to sides
Combustibles to back
Mantel
Not allowed in Canada
Adapter
(C)
Grounding Means
0"
0"
0"
0"
note:
Although this appliance is safe to operate with a
0" mantel height, a 2" (51mm) gap between the
appliance and the mantel is recommended in order
to lift the appliance on/off the rear wall bracket
hooks.