CONGRATULATIONS!
In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most
dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fireplace. Welcome to a Family of tens of thousands of satisfied LENNOX
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your LENNOX product.

TABLE OF CONTENTS

Introduction ............................................ page
General Information ................................ page
Operation/Care of Your Appliance .......... page
Variable Flame Adjustment ..................... page
Glass Cleaning ........................................ page
Maintenance ........................................... page
Removal and Installation ...................... page
Maintenance Schedule ............................ page
Burner Adjustments ................................ page
Flame Appearance and Sooting .............. page
Adjustment ............................................. page
Log Placement ........................................ page
Decorative Volcanic Stone Placement .... page
Millivolt Appliance Checkout ................... page
Electronic Appliance Checkout ............... page
Accessory Components .......................... page
Wiring Diagrams .................................... page 14
Warranty ................................................. page 14
Replacement Parts ................................. page 14
Product Reference Information .............. page 14
Lighting Instructions - Millivolt .............. page 16
Replacement Parts List ........................... page 22

INTRODUCTION

The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fire-
place heaters designed for residential applica-
tion.
2
Direct-Vent appliances operate with the com-
bustion chamber completely isolated from the
inside atmosphere. All air for combustion is
2
brought in from the outside and exhaust gases
2
are vented through the same direct vent, vent
3
system.
4
The millivolt appliances are designed to oper-
5
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
5
provides safe, efficient operation. External
electrical power is required to operate the
5
optional electrically powered components if
installed. Electrical power must be wired dur-
6
ing appliance installation.
7
The electronic appliances are designed to op-
7
erate on either natural or propane gas. An
7
electronic intermittent pilot system provides
8
safe, efficient operation. External electrical
power is required to operate these units.
9
9
These appliances comply with National Safety
Standards and are tested and listed by Omni-
9
Test Laboratories (Report No. 116-F-05-5) to
9
ANSI Z21.88-2002 (in Canada, CSA-2.33-
2002), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplace heaters.
The Installation must conform to local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54 , or the Natural Gas and Propane Installa-
tion Code, CSA B149.1 . The appliance, when
installed, must be electrically grounded in
accordance with local codes or, in the ab-
sence of local codes, with the National Elec-
trical Code, ANSI/NFPA 70 , or the Canadian
Electrical Code, CSA C22.1 .
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
WARNING: ELECTRONIC MODELS OF
THESE APPLIANCES ARE EQUIPPED
WITH A THREE-PRONG (GROUNDING)
PLUG UTILIZED IN CONNECTING THE
ELECTRONIC COMPONENTS TO THE
JUNCTION BOX IN THE LOWER COM-
PARTMENT. THIS GROUNDING PLUG
PROVIDES PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO THE PROP-
ERLY GROUNDED THREE-PRONG RE-
CEPTACLE. DO NOT CUT OR REMOVE
THE GROUNDING PRONG FROM THE
PLUG.

GENERAL INFORMATION

Note: Installation and repair should be performed
by a qualified service person. The appliance
should be inspected annually by a qualified pro-
fessional service technician. More frequent in-
spections and cleanings may be required due to
excessive lint from carpeting, bedding material,
etc. It is imperative that the control compart-
ment, burners and circulating air passage ways
of the appliance be kept clean.
S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.
Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies. Locate furniture and win-
dow coverings accordingly.
WARNING: THESE FIREPLACES ARE
VENTED HEATERS. DO NOT BURN
WOOD OR OTHER MATERIAL IN THESE
APPLIANCES.

Hide quick links: