Greenlee 847 Instruction Manual

Greenlee 847 Instruction Manual

Pvc heaters for 1/2" to 6" dia. pvc conduit

Advertisement

INSTRUCTION MANUAL
847 and 848
PVC HEATERS
for 1/2" to 6" Dia. PVC Conduit
Read and understand this material before operating
or servicing this equipment. Failure to understand how
to safely operate this tool could result in an accident
causing serious injury or death.
999 7773.7
© 2000 Greenlee Textron
IM 959 REV 8 3/00

Advertisement

Table of Contents
loading

Summary of Contents for Greenlee 847

  • Page 1 INSTRUCTION MANUAL 847 and 848 PVC HEATERS for 1/2" to 6" Dia. PVC Conduit Read and understand this material before operating or servicing this equipment. Failure to understand how to safely operate this tool could result in an accident causing serious injury or death.
  • Page 2: Table Of Contents

    This instruction manual is intended to familiarize operators and maintenance personnel with the safe operation and maintenance procedures for the Greenlee 847 and 848 PVC Heaters. This manual should be kept available to all operating and maintenance personnel. Greenlee Textron / Subsidiary of Textron Inc.
  • Page 3: Important Safety Instructions

    Safety is a critical factor in the design of Greenlee equipment. The best program starts with a safety-conscious operator. The information highlighted in this bulletin describes operating practices for the benefit of the workers who will use our equipment in their daily jobs.
  • Page 4: Save These Instructions

    SAVE THESE INSTRUCTIONS Additional copies of this manual are available upon request at no charge. Greenlee Textron / Subsidiary of Textron Inc. • Inspect tool before operating. Replace any worn, damaged or missing components with Greenlee replacement parts.
  • Page 5: Important Safety Instructions

    Do not use an adapter. PLUG RECEPTACLE 30-Amp/250 Volt Locking Plug and Receptacle Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070...
  • Page 6: Identification

    Conduit Length ... 178 cm (70") Dimensions ... 38 cm x 38 cm x 178 cm (15" x 15" x 70") Mass/Weight: 847 ... 33.5 kg (74 lbs.) 848 ... 35.4 kg (78 lbs.) Greenlee Textron / Subsidiary of Textron Inc.
  • Page 7: Operation

    This will prevent heating and deforming the straight section. Note: If using model 847, rotate the conduit by hand. 5. After the timer rings, check the PVC by lifting it at one end.
  • Page 8: Troubleshooting

    Heater does not heat up. Pilot light does not light up. Motor does not operate. Rollers do not operate. Greenlee Textron / Subsidiary of Textron Inc. PROBABLE CAUSE No power at supply circuit. Switch is faulty. Heating element is faulty.
  • Page 9: Wiring Diagram

    PVC Heaters for PVC Conduit Wiring Diagram HEATER PILOT LIGHT SWITCH #10 AWG MINIMUM Greenlee Textron / Subsidiary of Textron Inc. MOTOR (848 only) CONTROL BOX 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070 (KEY 24)
  • Page 10: Exploded View

    PVC Heaters for PVC Conduit Exploded View Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070...
  • Page 11: Parts List

    Decal, Damp Warning ... 1 503 1089.5 Tag, Attach Handle ... 2 503 1092.5 Conversion Kit (Convert an 847 into an 848; includes all items marked with †) Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070...
  • Page 12 Greenlee Textron / Subsidiary of Textron Inc. 4455 Boeing Drive, Rockford, IL 61109-2988 USA Customer Service (International): 815/397-7070 • Fax: 815/397-9247 Customer Service (North America): 800/435-0786 • Fax: 800/451-2632, 815/397-1865 Canada Fax: 800/524-2853 Printed in the U.S.A.

This manual is also suitable for:

848

Table of Contents