Carbon Brushes For Special Operating Conditions; Authorized Service; Humidity And Brush Wear - Baldor Reliance CDX7150 Installation & Operating Manual

Integral horsepower dc motor
Table of Contents

Advertisement

Carbon Brushes For Special Operating Conditions

Sometimes, there are problems if motor operation requires a different design or grade of carbon brush
than what was installed when the motor was built. These special operating conditions include long periods
of operation with loads that are significantly greater or less than rated load capacity. Also, operation in in
the presence of certain chemicals, or extreme temperature and humidity can degrade brush performance.
Generally, poor brush life or commutator wear can occur if one or more of the above conditions exist. The
brush used doesn't match the operating conditions.
Baldor offers optional brush grades for the above conditions and has replacement brushes available to
retrofit motors. Contact your local Baldor District Office or an Authorized Baldor Service Center for
technical assistance.
Do not change brush grades or the number of brushes per pole. Doing so may void the warranty and
make the motor unsafe. Contact your local Baldor district office or an authorized Baldor service center for
technical assistance.

Authorized Service

DC motors. Contact your local Baldor District Office for more information.

Humidity And Brush Wear

meter of dry air.
MN605
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Baldor catalog 505 (and the Baldor CD−ROM) lists service shops authorized to service Baldor
This curve represents 2 grains of water per cubic foot of dry air or 4.6 grams per cubic
Zone of Safe Brush Operation
110
100
90
80
70
60
Danger Zone
50
Too Low Humidity
40
30
10
20
Percent Relative Humidity
45
40
35
30
25
20
15
10
5
0
30
40
50
60
70
80
90 100
Maintenance & Troubleshooting 3-5

Advertisement

Table of Contents
loading

Table of Contents