Daikin EKHBRD-ACY1 Installation Manual page 6

Indoor unit for air to water heat pump system
Table of Contents

Advertisement

Application 2
Space heating and domestic hot water heating with one remote
controller installed with the unit, and another remote controller
installed in the living room.
C2
1
12
2
3
12
5
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat
exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
9
Domestic hot water
tank (optional)
The remote controller gives immediate feedback to the indoor
unit and by doing so it matches in a smart way the unit
performance to the demanded space heating requirements. In
this way there is no frequent start/stop of the unit or there are no
too big temperature fluctuations in the to be heated rooms. This
remote controller has also a smart logic functionality which
controls the combined space heating and domestic hot water
demand (e.g. if room temperature drops more than 3°C during
domestic hot water operation, the unit will automatically switch
back to space heating). The main remote controller (C1) is
installed in the living room and can access all settings (master).
The second remote controller (C2) can not access schedule and
field settings (slave).
Operation ON/OFF
Domestic water heating operation ON/OFF
Setting the leaving water temperature
Setting the room temperature
Quiet mode ON/OFF
Weather dependent set point operation
ON/OFF
Setting the clock
Programming the schedule timer
Schedule timer operation ON/OFF
Field settings
Error code display
Test operation
Room thermostat functionality
Refer to the chapter
"Electrical wiring work" on page 15
connecting the master and slave remote controller.
Installation manual
3
A
4
6
7
10 13
M
8
9
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion
valve
13
By-pass valve (field
supply)
C1
Remote controller
(master)
C2
Optional remote
controller (slave)
A
Installation place
B
Living room
Master
Slave
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Operable
Application 3
Space heating and domestic hot water heating with a single
remote controller installed with the unit, and the external room
thermostat installed in the living room.
B
Optionally the Daikin room thermostat EKRTR or
EKRTW can be connected to the Daikin system.
C1
Daikin can not guarantee neither good operation nor
reliability of the system if another thermostat is used.
For those reasons Daikin can not give warranty of the
system in such case.
11
1
12
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat
exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
9
Domestic hot water
tank (optional)
There is only a room thermostat on/off control. There is no smart
logic functionality for space heating. When there is simultaneous
demand of space heating and domestic hot water, the domestic
hot water operation is performed according to the minimum and
maximum timer operation.
about
C1
2
3
12
4
6
7
10 13
M
5
8
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion
valve
13
By-pass valve (field
supply)
C1
Remote controller
T
Room thermostat
A
Installation place
B
Living room
EKHBRD011~016ABV1+Y1 + EKHBRD011~016ACV1+Y1
Indoor unit for air to water heat pump system
A
B
T
11
9
4PW60970-1D – 05.2011