Table of Contents

Advertisement

Quick Links

Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide
First Published: 2017-09-27
Last Modified: 2018-03-01
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9300-FX

  • Page 1 Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide First Published: 2017-09-27 Last Modified: 2018-03-01 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com trademarks.
  • Page 3: Table Of Contents

    Minimizing Electromagnetic and Radio Frequency Interference Shock and Vibration Requirements Grounding Requirements Planning for Power Requirements Airflow Requirements Rack and Cabinet Requirements Clearance Requirements C H A P T E R 3 Installing the Switch Chassis Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 4 Overview of Racks General Requirements for Cabinets and Racks Requirements Specific to Standard Open Racks Requirements Specific to Perforated Cabinets Cable Management Guidelines A P P E N D I X B System Specifications Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 5 Rack Mount Kit NXK-ACC-KIT-1RU Rack Mount Kit N3K-C3064-ACC-KIT Accessory Kit A P P E N D I X E Site Preparation and Maintenance Records Site Preparation Checklist Contact and Site Information Chassis and Module Information Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 7: Preface

    Braces and a vertical bar within square brackets indicate a required choice within an optional element. Indicates a variable for which you supply values, in context where italics variable cannot be used. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 8: Related Documentation

    Downloadable Documentation • Knowledge Base Articles (KB Articles)are available at the following URL: https://www .cisco.com/c/en/us/support/cloud-systems-management/application-policy-infrastructure-controller-apic/products-configuration-examples-list.html • Cisco Application Centric Infrastructure Controller Release Notes • Cisco Application Centric Infrastructure Fundamentals Guide • Cisco APIC Getting Started Guide • Cisco ACI Virtualization Guide •...
  • Page 9 • Cisco ACI System Messages Reference Guide • Cisco APIC Layer 4 to Layer 7 Services Deployment Guide • Cisco APIC Layer 4 to Layer 7 Device Package Development Guide • Cisco APIC Layer 4 to Layer 7 Device Package Test Guide •...
  • Page 10: Documentation Feedback

    What's New in Cisco Product Documentation, at: https://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
  • Page 11: Overview

    Overview, on page 1 Overview The Cisco Nexus 9348GC-FXP switch (N9K-C9348GC-FXP) is a 1-RU fixed-port, L2/L3 switch, designed for ACI deployments. This switch has 48 100/1000-Megabit 1GBASE-T host ports, 4 10-/25-Gigabit SFP28 host ports, and 2 40-/100-Gigabit QSFP28 uplink ports. The chassis for this switch includes the following user-replaceable components: •...
  • Page 12: Bracket

    To determine which transceivers, adapters, and cables this switch supports, see the Cisco Transceiver Modules Compatibility Information document. The following figure shows the hardware features seen from the power supply side of the chassis. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 13 To determine the airflow direction of the modules installed in your switch, see the following table. Replaceable Modules Port-Side Intake Airflow Coloring Port-Side Exhaust Airflow Coloring Fans Burgundy Blue AC power supplies Burgundy Blue Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 14 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 15: Preparing The Site

    The following table lists the maximum altitude that this switch is tested to operate. This switch is rated to operate at altitudes from 0 to 13,123 feet (0 to 4,000 meters). If you operate this switch at a higher altitude Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 16: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 17: Shock And Vibration Requirements

    To operate the switch you must provision enough power from the power source to cover the requirements of both the switch and a power Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 18: Airflow Requirements

    Depending on which side of the switch faces the cold aisle, you must have fan and power supply modules that move the coolant air from the cold aisle to the hot aisle in one of the following ways: Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 19: Rack And Cabinet Requirements

    Work with your cabinet vendors to determine which of their cabinets meet the following requirements or see the Cisco Technical Assistance Center (TAC) for recommendations: • Use a standard 19-inch (48.3-cm), four-post Electronic Industries Alliance (EIA) cabinet or rack with mounting rails that conform to English universal hole spacing per section 1 of the ANSI/EIA-310-D-1992 standard.
  • Page 20: Clearance Requirements

    Width of the front clearance area (this equals the width of the chassis with two rack-mount brackets attached to it) Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 21: Safety

    Starting the Switch, on page 23 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071—Warning Definition IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger.
  • Page 22: Installation Options With Racks And Cabinets

    • Ensure that the chassis can be adequately grounded. If the switch is not mounted in a grounded rack, we recommend connecting both the system ground on the chassis directly to an earth ground. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 23: Unpacking And Inspecting The Switch

    For the contents of these kits, see the Additional Kits. Step 2 Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready: • Invoice number of shipper (see packing slip) Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 24: Installing The Switch

    Determine which end of the chassis is to be located in the cold aisle as follows: • If the switch has port-side intake modules (fan modules with burgundy coloring), position the switch so that its ports will be in the cold aisle. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 25 Repeat Step 1 for the other front rack-mount bracket on the other side of the switch and be sure to position that bracket the same distance from the front of the switch. Step 2 Install the two rear rack-mount brackets on the chassis as follows: Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 26 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 27 Holding the chassis level, insert two screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount brackets (using a total of four screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 28: Installing The Switch Into A Two-Post Rack

    To install the switch, you must attach mounting brackets to the switch and secure the switch to the rack. Installation in racks other than 19-inch racks requires a bracket kit not included with the switch. The following figure shows the standard 19-inch mounting brackets. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 29 Position the bracket so that four of its screw holes are aligned to the screw holes on the side of the chassis as shown in the following figure. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 30 Repeat previous step for the other front rack-mount bracket on the other side of the switch and be sure to position that bracket the same distance from the front of the switch. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 31: Grounding The Chassis

    Warning Statement 1046—Installing or Replacing the Unit When installing or replacing the unit, the ground connection must always be made first and disconnected last. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 32 After you install the chassis, prepare the other end of the grounding wire and connect it to an appropriate grounding point in your site to ensure an adequate earth ground for the switch. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 33: Starting The Switch

    Step 5 Verify that the system software has booted and the switch has initialized without error messages. Step 6 Complete the worksheets provided in Site Preparation and Maintenance Records for future reference. Note Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 34 Starting the Switch A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus configuration guide.
  • Page 35: Connecting The Switch To The Aci Fabric

    93180YC-EX, 93180YC-FX, 9332PQ, 9348GC-FXP, 9372PX, 9372PX-E, 9372TX, 9372TX-E, 9396PX, and 9396TX switches) • Spine switches (Cisco Nexus 9336PQ, 9364C, 9504, 9508, and 9516 switches) As shown in the following figure, each APIC is connected to one or two leaf switches and each leaf switch should be connected to every spine switch in the same fabric.
  • Page 36: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 37: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) ACI-mode leaf switches (Cisco Nexus 93108TC-EX, 93108TC-FX, 93120TX, 93128TX, 93180LC-EX, 93180YC-EX, 93180YC-FX, 9332PQ, 9348GC-FXP, 9372PX, 9372PX-E, 9372TX, 9372TX-E, 9396PX, or 9396TX) to each Application Policy Infrastructure Controller (APIC) in your ACI fabric.
  • Page 38: Connecting Leaf Switches To Spine Switches

    Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 39 (Cisco Nexus 9504, 9508, or 9516 switch) or on each Cisco Nexus 9336PQ or 9364C spine switch. The number of line cards in a spine switch depends on the model of the spine switch (the Cisco Nexus 9504 supports four line cards, the Cisco Nexus 9508 supports up to eight line cards, and the Cisco Nexus 9516 supports up to 10 line cards in ACI-mode).
  • Page 40 • If there are modular switches in the fabric, their ACI-mode line cards must already be installed. The line cards can be of the following types: • 36-port 40-Gigabit (N9K-X9736PQ) • 32-port 100-Gigabit (N9K-X9732C-EX) (supported by Cisco Nexus 9504 and 9508 modular switches) Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 41: Setting Up An Optional Console Interface

    Insert the appropriate transceiver into an active uplink port on the leaf switch. Note For 1- or 10-Gigabit Ethernet on a Cisco Nexus 93108TC-EX or 93180YC-EX switch or a N9K-X9732C-EX, N9K-X9736PQ, or N9K-X9432PQ line card, insert a QSFP-to-SFP adapter (CVR-QSFP-SFP10G) before inserting an SFP+ transceiver.
  • Page 42: Setting Up An Optional Management Connection

    Setting Up an Optional Management Connection What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 43 • Inspect routinely for dust and damage. If you suspect damage, clean and then inspect fiber ends under a microscope to determine if damage has occurred. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 44 Connecting the Switch to the ACI Fabric Maintaining Transceivers and Optical Cables Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 45: Replacing Components

    On the fan module that you are removing, press the two sides of the fan module handle next to where it connects to the fan module and pull on the handles enough to unseat it from its connectors. Step 2 Holding the handle, pull the module out of the chassis. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 46: Installing A Fan Module

    • NXA-PDC-440W-PI (440-W, port-side intake (burgundy latch) power supply) Replacing an AC Power Supply You can replace an AC power supply during operations so long as the other power supply provides to the switch. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 47 Make sure that the other end of the power cable is attached to the appropriate power source for the power supply. Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper Note cable to connect the switch to your outlet receptacle. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 48 Verify that the power supply is operational by making sure that the power supply LED is green. For information on what the power supply LEDs indicate, see Power Supply LEDs, on page Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 49: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 50: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 51: System Specifications

    Width Depth Height Cisco Nexus 9348GC-FXP 17.3 inches (43.9 cm) With AC power 1.72 inches (4.4 cm) (1 RU) supplies 19.7 inches (49.9 cm) With DC power supplies 21.0 inches (53.34 cm) Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 52: Switch And Module Weights And Quantities

    Some power supplies might have UL listed capabilities that are greater than the maximum power requirements for a switch. To determine the power consumption characteristics for the switch, use the typical and maximum requirements listed in the following table. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 53: Power Specifications

    Power supply standby voltage 12 VDC Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum certified) Form factor RSP1 440-W DC Power Supply Specifications These specifications apply to the following power supplies: • NXA-PDC-440W-PE • NXA-PDC-440W-PI Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 54: Power Cable Specifications

    Argentina CAB-250V-10A-AR 250 V, 10 A, 8.2 feet (2.5 m) Australia CAB-9K10A-AU 250 VAC, 10 A, 3112 plug, 8.2 feet (2.5 m) Brazil CAB-250V-10A-BR 250 V, 10 A, 6.9 feet (2.1 m) Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 55: Regulatory Standards Compliance Specifications

    Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. Safety • UL 60950-1 Second Edition • CAN/CSA-C22.2 No. 60950-1 Second Edition • EN 60950-1 Second Edition • IEC 60950-1 Second Edition • AS/NZS 60950-1 • GB4943 Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 56 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 57: Leds

    Amber Port admin state is 'Disabled, or the SFP is absent, or both. Port admin state is 'Enabled' annd SFP is present, but interface is not connected. Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 58: Fan Module Leds

    Power supply warning—possibly one of the following conditions: • High voltage • High power • Low voltage • Power supply installed in chassis but not connected to a power source • Slow power supply fan Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 59: Appendix D Additional Kits

    The following table lists and illustrates the contents for the 1RU rack-mount kit (NXK-ACC-KIT-1RU). Illustration Description Quantity Rack-mount kit • Front brackets (2) • Rear brackets (2) • Slider rails (2) • M4 Phillips pan-head screws Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 60: Rack Mount Kit N3K-C3064-Acc-Kit

    • M4 x 7 mm mounting screws (16) Console cable with DB-9F and RJ-45F connectors Ground lug kit 1 kit • Two-hole lug (1) • M4 x 8-mm Phillips pan-head screws (2) Not applicable EAC Compliance document Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 61 China Note If you do not receive a part listed in this document, contact Cisco Technical Support at this URL: https://www.cisco.com/warp/public/687/Directory/DirTAC.shtml. If you purchased this product through a Cisco reseller, you might receive additional contents in your kit, such as documentation, hardware, and power cables.
  • Page 62 Additional Kits Additional Kits Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 63: Site Preparation And Maintenance Records

    Your completion of each task ensures a successful switch installation. Planning Activity Verification Time and Date Space evaluation: Space and layout Floor covering Impact and vibration Lighting Physical access Maintenance access Environmental evaluation: Ambient temperature Humidity Altitude Atmospheric contamination Airflow Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 64: Contact And Site Information

    (transceivers) EMI evaluation: Distance limitations for signaling Site wiring RFI levels Contact and Site Information Use the following worksheet to record contact and site information for the installation. Contact person Contact phone Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 65: Chassis And Module Information

    Domain name IP broadcast address Gateway/router address DNS address Use the following worksheet to record information about the modules in the switch. Module Slot Module Type Module Serial Number Notes Fan module 1 Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...
  • Page 66 Site Preparation and Maintenance Records Site Preparation and Maintenance Records Module Slot Module Type Module Serial Number Notes Fan module 2 Fan module 3 Power Supply 1 Power Supply 2 Cisco Nexus 9348GC-FXP ACI Mode Hardware Installation Guide...

This manual is also suitable for:

Nexus 9348gc-fxp

Table of Contents