LG DLGX3371W Service Manual page 42

Electric & gas dryer
Table of Contents

Advertisement

Test 5
NOTE: This test has two parts. The best test of the door switch system is done in the diagnostic mode. This
FUNCTIONAL TEST will test the door switch, wiring harness and PCB operation. If the results of this test are
normal, the door switch system and PCB response are normal. The problem is somewhere else.
FUNCTIONAL TEST (Control)
1. Enter the diagnostic mode. (See DIAGNOSTIC TEST MODE.)
2. With the door closed, press the START/PAUSE button once. The dryer will start tumbling without heat.
3. Open the door. The drum will stop tumbling. The "dE" error code should be displayed, the chime should sound seven times (if turned on), and
the drum light (if equipped) should come on. If the "dE" error code is not displayed or the light does not come on, proceed with the
MECHANICAL TEST below. If the error displays and light comes on, the door switch is working properly.
WH4
Disconnect the WH1 and BL3 connector
from the main PCB.
Measure the resistance between the
NA6-
(GN) pin and a chassis
ground screw.
Is the resistance <1
?
YES
Disconnect the BL2 and WH4 connector
from the main PCB.
Measure the resistance between
BL2-
(WH) and WH4-
Is the resistance <1
with the
door closed and
open?
NO
*Skip this step if the dryer does not have
a drum light.
Disconnect the WH4 and the black tab
relay connectors from the main PCB.
Measure the resistance between
WH4-
(YL) and WH4-
Is the resistance <1
with the door
opened and
with the door closed?
YES
Refer to the individual door switch and light
bulb/socket component tests.
42
NO
YES
(YL).
with the door
NO
(BK).
• Check all wiring
harness
connections wire
and ground
screws.
• Replace the main
PCB.
• Replace the light
bulb.
• Replace the light
socket.

Hide quick links: