Specifications - Mitsubishi Electric Mr. Slim PCA Series Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for Mr. Slim PCA Series:
Table of Contents

Advertisement

4

SPECIFICATIONS

Service Ref.
Mode
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) × No.
Fan motor output
Airflow(Low-High)
External static pressure
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe I.D.
Dimensions
Weight
Service Ref.
Mode
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) × No.
Fan motor output
Airflow(Low-High)
External static pressure
Operation control & Thermostat
Noise level(Low-High)
Unit drain pipe I.D.
Dimensions
Weight
kW
A
A
kW
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
W
mm(in.)
D
mm(in.)
H
kg(lbs)
kW
A
A
kW
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
W
mm(in.)
D
H
mm(in.)
kg(lbs)
9 9
PCA-RP71HAQ
Cooling
Single phase, 50Hz, 230V
0.09
0.43
0.86
Stainless steel
Plate fin coil
Sirocco fan (direct) × 2
0.04
17-19(600-670)
0(direct blow)
Remote controller & built-in
34-38
26(1)
1,136(44-3/4)
650(25-5/8)
280(11)
41(90)
PCA-RP125HAQ
Cooling
Single phase, 50Hz, 230V
0.26
1.19
2.38
Stainless steel
Plate fin coil
Sirocco fan (direct) × 4
0.08 + 0.08
30-38(1,060-1,350)
0(direct blow)
Remote controller & built-in
44-50
26(1)
1,520(59-7/8)
650(25-5/8)
280(11)
56(124)
Heating
0.09
0.43
0.86
Heating
0.26
1.19
2.38