STM
1=Reducing identification sensitivity during tuning in
High
HCO
0=Compensating vertical output 1=Compensation
horizontal/vertical output
Vertical protection 1=Identification and protection
EVG
0=Identification only
High voltage (X-ray protection )
PRD
and protection 0=Identification only
COR
Coring: 1=On 0=Off
MENU 11
Others
OSO
1=Switch-off in vertical overscan function
CS1.CS0
CVBS-2 OUTPUT ( for TDA885X only)
AST
Auto Startup 0=AUTO 1=Startup by MUCH
FFI
IF-PILL time constant 0=Normal 1=Fast
EBS
Expanding blue level stretch 1=ON
FCO
Color killer 0=Normal 1=Not kill
MENU 12
Option switch
OPT.AV2
1=With AV2
OPT.AV3
1=With AV3
OPT.YCbCr
YUV component input 1 Yes 0=No
OPT.COLOR
Color system 0=NTSC 1=PAL M/N—NTSC
OPT.V-CHIP
V-CHIP 1=Yes
OPT.CCD
CCD 1=Yes
OPT.PWR-ON
0=Soft on 1=Instant on
SRCH SPEED
0=Slow search 1= Fast search
ROM CORREC
ROM correction (fixed to 0)
MSP/TDA
1 BTSC(MSP3440) 0=STEREO/ MONO
Notes: (1) For MCR68TF800 and MCR68420, OPT.AV3 should be changed to 0, POT.DVD should be
changed to 1; For MCR66R400, OPT.SHS should be changed to 0.
(2) The data sheet may differ dependent on different modes.
(3) The data sheet may differ dependent on different CRTs for the same model.
(4) Do not adjust I
(5) The remote jigs on neighboring work position cannot affect each other.
SERVICE MANUAL
voltage
fluctuation
2
C data with the remote jig unless necessary.
0
compensation
1
0
1=Identification
1
1
1
0
1
0
1
0
1
1
0
1
1
1
0
0
0
0