3.

How to set the different addresses.

When two indoor units are installed in one room, the two wireless remote con-
trollers can be set for different addresses.
1) In the same way as when connecting to an HA system, remove the metal
plate electrical wiring cover.
2) Cut the address jumper (JA) on the printed circuit board.
3) Cut the address jumper (J4) in the remote controller.