Electrical Safety - LG LP155CED1 Owner's Manual

Packaged terminal air conditioner/heat pump
Hide thumbs Also See for LP155CED1:
Table of Contents

Advertisement

Electrical Safety

Electrical Data
115V~
NOTICE
The shape may be different according to its model.
Use Wall Receptacle
Standard 208/230V, 3-wire
grounding receptacle rated 15A
Standard 208/230V, 3-wire
grounding receptacle rated 20A
Standard 208/230V, 3-wire
grounding receptacle rated 30A
Standard 265V grounding
receptacle rated 20A
Standard 265V grounding
receptacle rated 30A
NOTICE
DO NOT USE AN EXTENSION CORD on 230, 208,
and 230/208,265Volt units.
All wiring should be made in accordance with local
electrical codes and regulations.
Aluminum house wiring may pose special problems.
Consult a qualified electrician.
230V~
Power Supply
Use 15 AMP. time
delay fuse or 15 AMP.
Circuit breaker.
Use 20 AMP. time
delay fuse or 20 AMP.
Circuit breaker.
(2500W Heater →15 AMP
Circuit Breaker)
Use 30 AMP. time
delay fuse or 30 AMP.
Circuit breaker.
Use 20 AMP,time delay
fuse or 20 AMP
Circuit breaker
(2000W Heater →15 AMP
Circuit Breaker)
Use 30 AMP,time delay
fuse or 30 AMP
Circuit breaker
Power cord may include a current
265V~
interrupter device. A test and reset
button is provided on the plug case. The
device should be tested on a periodic
basis by first pressing the TEST button
and then the RESET button. If the TEST
button does not trip or if the RESET
button will not stay engaged,
discontinue use of the air conditioner
and contact a qualified service
technician.
Never push the test button during operation
Otherwise this plug can damaged.
This device contains chemicals, including lead, known
to the State of California to cause cancer, birth
defects, or other reproductive harm.
Wash hands after handling.
Do not remove, modify, or immerse this plug.
If this device trips, the cause should be corrected
before further use.
The conductors inside this cord are surrounded by
shields, which monitor leakage current.
These shields are not grounded.
Periodically examine the cord for any damage. Do
not use this product in the event the shields become
exposed.
Avoid shock hazard! This unit cannot be serviced.
Opening the tamper-resistant, sealed portion of the
unit voids all warranties and performance claims.
This unit is not intended to be an ON/OFF switch.
• If unit equipped with cords and plugs as long as
they are installed with sub-bases, and the cord and
plug are enclosed within the sub-base.
• The sub-base must have means for permanent
connection.
• The sub-base must have an outlet for the connection
of the cord and plug.
• To complete the installation of this PTAC, there must
be a sub-base.
Electrical Safety
Owner's Manual 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp155hed1Lp093cd3a3828a20255j

Table of Contents