INSTALLATION MANUAL
AIR
CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
This product contains Fluorinated Greenhouse Gases. (R410A)
WALL MOUNTED
Original instruction
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V.
Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si,
Gyeongsangnam-do, KOREA
For more information, Refer to the CD or LG Web site (www.lg.com).
P/NO : MFL67855410
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG MS15SQ

  • Page 1 This product contains Fluorinated Greenhouse Gases. (R410A) WALL MOUNTED Original instruction [Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands [Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA For more information, Refer to the CD or LG Web site (www.lg.com).
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid danger- ous situations and ensure peak performance of your product WARNING It can result in serious injury or death when the directions are ig- nored CAUTION It can result in minor injury or product damage when the direc-...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS • For electrical work, contact the dealer, seller, a qualified elec- trician, or an Authorized Service Center. - Do not disassemble or repair the product. There is risk of fire or electric shock. • Always ground the product. - There is risk of fire or electric shock.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS • There is a risk of fire and explosion. - Inert gas (nitrogen) should be used when you check plumb- ing leaks, cleaning or repairs of pipes etc. If you are using combustible gases including oxygen, product may have the risk of fires and explosions.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS • Use two or more people to lift and transport the product. - Avoid personal injury. • Do not install the product where it will be exposed to sea wind (salt spray) directly. - It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS IMPORTANT SAFETY IN- INSTALLATION STRUCTIONS Select the best Location INSTALLATION PARTS Fixing Installation Plate Drill a Hole in the Wall INSTALLATION TOOLS Flaring Work INSTALLATION MAP Connecting the Piping Checking the Drainage Installation of filters Test Running...
  • Page 7: Installation Parts

    INSTALLATION PARTS INSTALLATION PARTS Name Quantity Shape Installation plate 1 EA The feature can be changed according to type of model. Type "A" screw 5 EA Type "B" screw 2 EA Type "C" screw 2 EA Remote control 1 EA holder Screws for fixing panels are attached to decoration panel.
  • Page 8: Installation Map

    INSTALLATION MAP INSTALLATION MAP Installation plate Sleeve Bushing-Sleeve Putty(Gum Type Sealant) Bend the pipe as closely on the wall as possible, but be careful that it doesn't break. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters Saddle and pour water into the heat...
  • Page 9: Installation

    INSTALLATION INSTALLATION Select the best Location Fixing Installation Plate - There should not be any heat or steam near The wall you select should be strong and solid the unit. enough to prevent vibration - Select a place where there are no obstacles Mount the installation plate on the wall around of the unit.
  • Page 10: Drill A Hole In The Wall

    INSTALLATION Drill a Hole in the Wall Burrs removal 1. Completely remove all burrs from the cut - Drill the piping hole with a ø65mm hole core cross section of pipe/tube. drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the 2.
  • Page 11: Connecting The Piping

    INSTALLATION Pull back the tubing holder. Handle Remove pipe port cover and positioning the tubing Yoke Tubing holder Indoor unit back side view Cone Copper pipe Clamp handle Red arrow mark Right Left Backwards Downwards Check Compare the flared work with the figure * The feature can be changed according to type of model.
  • Page 12 INSTALLATION Bad case Installation of Indoor Unit - Following bending case from right to left di- Hook the indoor unit onto the upper por- rectly may cause damage to the tubing. tion of the installation plate.( engage the three hooks at the top of the indoor unit with the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving...
  • Page 13 INSTALLATION <Right side piping> CAUTION If the drain hose is routed inside the room insulate the hose with an insulation mate- rial* so that dripping from sweating conden- sation) will not damage furniture or floors. * Foamed polyethylene or equivalent is recommended.
  • Page 14 INSTALLATION Wrap the insulation material Finishing the indoor unit around the connecting portion. installation Overlap the connection pipe insulation ma- Mount the tubing holder in the original terial and the indoor unit pipe insulation positon. material. Bind them together with vinyl Ensure that the hooks are properly seated tape so that there may be no gap.
  • Page 15: Checking The Drainage

    INSTALLATION Checking the Drainage Do not make drain piping like the follow- ing. To check the drainage. Pour a glass of water on the evaporator. Do not raise Ensure the water flows through the drain hose of the indoor unit without any leak- age and goes out the drain exit.
  • Page 16: Installation Of Filters

    INSTALLATION Installation of filters Test Running - Check that all tubing and wiring are properly Premium type connected. Pull out the 3M Filter from the separately - Check that the gas and liquid side service packed plastic bag. valves are fully open. Detach the two nitto tapes from the filter.

This manual is also suitable for:

Ms12sqMs12aqMs09sqMs09aq

Table of Contents