E19 Indoor Unit Operation Check, Drain Pump Motor Check Setting Error - Mitsubishi Heavy Industries FDTC25VH1 Service Manual

Inverter residential air to air heat pump type
Hide thumbs Also See for FDTC25VH1:
Table of Contents

Advertisement

Error code
Remote control:
E19
1. Applicable model
All models
2. Error detection method
After indoor operation check,
when the communication
between indoor and outdoor
unit is established and SW7-1 is
still kept ON.
3. Condition of error displayed
Same as above
4. Presumable cause
Mistake in SW7-1 setting
(Due to forgetting to turn OFF
SW7-1 after indoor operation
check)
Note:
LED
Green
Red
Keeps flashing 1-time flash
Indoor
5. Troubleshooting
Diagnosis
E19 occurs
when the power ON
Is SW7-1
on the indoor unit control
PCB ON ?
104
-
Content
Indoor unit operation check,
drain pump moter check setting error
NO
YES
-
'20 • SR-SM-285
Countermeasure
Defective indoor unit
control PCB (Defective
SW7) ➞ Replace.
Turn SW7-1 on the indoor
unit control PCB OFF and
reset the power.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srr35zs-wSrr25zs-wFdtc35vh1

Table of Contents