Navien NPN Installation & Operation Manual page 37

Non-condensing water heaters
Table of Contents

Advertisement

*The manufacturer shall specify a minimum clearance or state "Not applicable" in the table and/or instructions.
1) The minimum distance from adjacent public walkways, adjacent buildings, openable windows, and building openings shall
not be less than those values specified in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or the Natural Gas and
Propane Installation Code, CSA B149.1;
2) Information on preventing blockage by snow; and
3) Information on protecting building materials from degradation by flue gases.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings
and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code
Note
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
If locally adopted installation codes specify clearances different than those illustrated, then the
most stringent clearance shall prevail.
For outdoor models (other than direct vent)
Ref Description
A
Clearance above grade, veranda, porch, deck, or balcony
B
Clearance to window or door that may be opened
C
Clearance to permanently closed window
Vertical clearance to ventilated soffit located above the terminal
D
within a horizontal distance of 2 ft (61 cm) from the center line
of the terminal
E
Clearance to unventilated soffit
F
Clearance to outside corner
G
Clearance to inside corner
Clearance to each side of center line extended above meter/
H
regulator assembly
I
Clearance to service regulator vent outlet
Clearance to nonmechanical air supply inlet to building or the
J
combustion air inlet to any other appliance
K
Clearance to a mechanical air supply inlet
Clearance above paved sidewalk or paved driveway located on
L
public property
M
Clearance under veranda, porch deck, or balcony
* The manufacturer shall specify a minimum clearance or state "Not applicable" in the table and/or instructions.
1) The minimum distance from adjacent public walkways, adjacent buildings, openable windows, and building openings shall
not be less than those values specified in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or the Natural Gas and
Propane Installation Code, CSA B149.1;
2) Information on preventing blockage by snow; and
3) Information on protecting building materials from degradation by flue gases.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings
and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code
Note
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
If locally adopted installation codes specify clearances different than those illustrated, then the
most stringent clearance shall prevail.
36
Installing the Water Heater
Non-Direct Vent Installation Clearance
12 in (30 cm)
4 ft (1.2 m) below or to side of opening;
1 ft (300 mm) above opening
As specified by the manufacturer*
As specified by the manufacturer*
As specified by the manufacturer*
As specified by the manufacturer*
As specified by the manufacturer*
As specified by the manufacturer*
As specified by the manufacturer*
4 ft (1.2 m) below or to side of opening;
1 ft (300 mm) above opening
3 ft (91 cm) above if within 10 ft (3 m) horizontally
7 ft (2.13 m) for mechanical draft systems (Category
I appliances). Vents for Category II and IV appliances
cannot be located above public walkways or other
areas where condensate or vapor can cause a
nuisance or hazard
As specified by the manufacturer*
1

Advertisement

Table of Contents
loading

Table of Contents