  • Page 1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-18LV03 HSU-22LV03 HSU-24LV03 Please read this operation manual before using the air conditioner No.0010563231 http://splitoff.ru/tehn-doc.html...
  • Page 2 Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe.
  • Page 3 Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver.
  • Page 4: Safety Instruction

    Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation.
  • Page 5 Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT...
  • Page 6: Parts And Functions

    Parts and Functions Indoor unit Outlet Display board Air filter(inside) Inlet Air Purifying Filter UV light degerming (inside) device (inside) Inlet grille Anion generator (inside) Vertical flap (adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) Outdoor unit OUTLET CONNECTING PIPING AND ELECTRICAL WIRING...
  • Page 7 Parts and Functions 9. HEALTH button Used to set healthy operation. 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display AUTO 13. LOCK display 14. SWING UP/DOWN display 15. SLEEP display FRESH 16.
  • Page 8 Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: FRESH 1. Press CLOCK button,"AM" or "PM" flashes. 2. Press to set correct time. Each press will increase or decrease STERILIZE 1 min.
  • Page 9 Operation HEALTH operation Remote controller 1.Unit start Press ON/OFF on the remote controller, unit starts. 2.Health anion function Press HEALTH button. For each press, is displayed. Air conditioner starts health anion function operation. For twice press, disappears,the operation stops. 3.UV light degerming function Press STERILIZE button ,"...
  • Page 10 Operation Auto Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL Then Select Auto operation 3.Select temp.setting Press TEMP.
  • Page 11: Cool Operation

    Operation Cool Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL Then Select COOL operation 3.Select temp.setting Press TEMP.
  • Page 12: Dry Operation

    Operation Dry Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL Then Select DRY operation 3.Select temp.setting Press TEMP.
  • Page 13: Fan Operation

    Operation Fan Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL Then Select FAN operation 3.Fan speed selection Press FAN button.
  • Page 14 Operation Air Flow Direction Adjustment 1.Status display of air sending Vertical flap Horizontal louvers Pos.1 Pos.1 Pos.2 Pos.2 Pos.3 Pos.3 FRESH Pos.4 Pos.4 STERILIZE Pos.5 Pos.5 Pos.6 Pos.6 (Auto swing) Pos.7 Pos.8 2.Up and down air flow direction For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN...
  • Page 15 Operation Sleep Operation Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. SLEEP operation starts SLEEP operation stops Use of SLEEP function Approx.6hrs After the unit starts, set the operation status, then press SLEEP button before which the Rises 1 1 hr...
  • Page 16 Operation Timer On/Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Remote Controller Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK...
  • Page 17 Operation Timer On-Off Operation Set clock correctly before starting TIMER operation. Remote Controller 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK...
  • Page 18 Operation Health airflow Operation 1.Press ON/OFF to starting Remote controller The liquid crystal will display the working state of last time (Except timer, sleeping, power/soft and health airflow). Setting the comfort work conditions. 2.The setting of health airflow function 1).Press the button of health airflow, appears on the display.
  • Page 19: Emergency And Test Operation

    Operation Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
  • Page 20: Maintenance

    Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind Use the louvers effectively...
  • Page 21: Air Filter Cleaning

    Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral Do not use water, wipe the controller with a detergent diluted with water.Wring the water dry cloth.Do not use glass cleaner or chemical...
  • Page 22 Maintenance Replancement of Air Purifying Filter 1.Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Attach new Air Purifying Filter Put air purifying filter appliances into the Detach old Air Purifying Filter...
  • Page 23 Maintenance To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 C,cooling mode and High speed fan mode for 2-3 hours. Put off the power supply cord.
  • Page 24 Maintenance Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the earthing cable. Caution Incomplete earthing may cause an electric shock.
  • Page 25: Troubleshooting

    Trouble shooting Before asking for service, check the following first. Phenomenon Cause or check points The system does not restart When unit is stopped, it won't restart immediately. immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.