Water Supply And Drain Connections - Scotsman CU0515GA1 Installation And User Manual

Table of Contents

Advertisement

Wa ter Sup ply And Drain Con nec tions
General
When choosing the water supply for the ice cuber
consideration should be given to:
a) Length of run
b) Water clarity and purity
c) Adequate water supply pressure
Low water pressure, below 20 psi may cause a
malfunction.
Water containing excessive minerals will tend to
produce cloudy colored ice cubes, plus scale
build-up on parts of the water system.
Water Supply
The recommended water supply line is a 3/8" o.d.
copper tube, the water pressure must have a
minimum incoming pressure of 20 psig.
Connect the tubing to the 3/4" GAS / BSPP thread
water inlet fitting at the back of the ice maker. An
adapter is available, the part numbers are:
F733219-03 and F640134-00.
Water Inlet
Connection
Back View of Utility Connections
Water Drain
The recommended drain tube is a plastic or flexible
tube with 18 mm (3/4") I.D. which runs to an open
trapped and vented drain.
Note: Although soft, easily kinked vinyl tubing is
not recommended for a drain, a short length of ¾"
ID vinyl tubing is required to connect a rigid drain
tube to the 20 mm (25/32") fitting on the back of
the machine.
NOTE. The water supply and the water drain must
be installed to conform to the local code. In some
case a licensed plumber and/or a plumbing permit
is required.
Water Drain
Connection