Water Chemistry Requirements - Westinghouse 080 Use And Care Manual

Medium duty commercial three element electric water heaters
Table of Contents

Advertisement

TOP VIEW
Figure 2 - Dimensional Drawing
Storage
Models
A
Capacity
080
80
6 1/2"
100
100
7 1/4"
115
115
Table 2 - Specifications and Dimensions - See Table 3 for a List of Available Elements
C. Water Chemistry Requirements
Chemical imbalance of the water supply may affect efficiency and
cause severe damage to the appliance and associated equipment.
Water quality must be professionally analyzed to determine
whether it is necessary to treat the water. Various solutions are
available to adjust water quality. Adverse water quality will affect
the reliability of the system. In addition, operating temperatures
o
above 135
F will accelerate the build-up of lime scale and possibly
shorten appliance service life. Failure of an appliance due to
lime scale build-up, low pH, or other chemical imbalance IS NOT
covered by the warranty.
The water must be potable, free of corrosive chemicals, sand, dirt,
and other contaminates. It is up to the installer to ensure the water
does not contain corrosive chemicals or elements that can damage
the heat exchanger. Potable water is defined as drinkable water
supplied from utility or well water in compliance with EPA secondary
Specifications and Dimensions
B
C
D
E
60"
69"
23 1/4"
52"
61"
8"
27"
60"
69"
FRONT VIEW
Hot /
Shipping
F
Cold
Weight
Inlets
(Lbs. Est.)
26"
165
3/4"
220
NPT
30"
240
maximum contaminant levels (40 CFR Part 143.3). If the water contains
contaminants higher than outlined by the EPA, water treatment is
recommended and additional, more frequent maintenance may be
required.
If you suspect that your water is contaminated in any way, discontinue
use of the appliance and contact an authorized technician or licensed
professional.
Water pH between 6.5 and 8.5
• pH levels below 6.5 can cause an increase in the rate of
corrosion. pH of 8.5 or higher can potentially cause lime
scale build-up
• Maintain water pH between 6.5 and 8.5. Check with litmus
paper or have it chemically analyzed by a local water
treatment company.
• If the pH is not between 6.5 and 8.5, consult a local water
treatment company for solutions.
whl-647 Rev. 000 Rel. 000 Date 11.1.17
Water Temperature Ratings
Min.
Max.
High
Delivered
Delivered
Temp.
Temp.
Temp.
Limit
o
135
o
F
181
F
200
(57.2 C)
(82.8 C)
(93.3 C)
5
o
F

Advertisement

Table of Contents
loading

This manual is also suitable for: