CONNECT VENT

1.
Connect vent to exhaust outlet
Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 102 mm (4") clamp.
2.
Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.

LEVEL DRYER

1.
Level dryer
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing system
to operate correctly.
Not Level
2.
Tighten and adjust leveling legs
If dryer is not level or the same height as the washer, prop up
using a wood block. Use wrench to adjust legs up or down
and check again for levelness. Once legs are level, make sure
all four legs are snug against the floor before tightening them.
LEVEL
Not Level