60 LIMITED WARRANTY
Problem
• Flames too big on
converted cooktop
(NP  LP)
• Flame is too small or
too large
• Gas smell
The cost of repair or replacement under the above excluded circumstances shall be borne by the
consumer.
TO OBTAIN WARRANTY SERVICE AND ADDITIONAL INFORMATION
Call 1-800-243-0000 and select the appropriate option from the menu.
Or visit our website at http://www.lg.com
Or by mail: LG Electronics Customer Service P.O. Box 240007 Huntsville, AL 35813 ATTN: CIC
Cause
The installer missed part of the conversion.
(Check 3 parts: regulator, cooktop nozzles,
broil/bake nozzles.)
cooktop nozzles
regulator
1. Variable gas pressure
2. Installer did not check
Center adjustment screw
Improper connection
Flexible Connector Hookup
Pressure
regulator
/
"
1
Adapter
2
Flex connector
(6 ft. max.)
/
"
Adapter
1
2
• Check with installer first
• Refer to installation manual
broil/bake nozzles
• Check with installer first
• Check with installer first
/
" Adapter
1
2
Gas shut-off valve
/
" or
/
" Gas pipe
1
3
2
4