8. Commands and monitoring from the computer

Across the network, instructions (commands and frequency) can be sent to each inverter and the
operating status of each inverter can be monitored.

8.1. Communication commands (commands from the computer)

■ Communication command (Communication number: FA00)
Commands can be executed on inverter frequencies and operation stop through communications.
The VF-S11 series can enable command and frequency settings through communications irrespec-
tive of settings of the command mode (  ) and frequency mode (  ). However, if "48:
Forced change from communication to local," "52: Forced operation," or "53: Fire speed" is set by in-
put terminal function selection (  to  ), a change to a command other than communica-
tion and to a frequency command is feasible through a contact on the terminal board.
Once the communication command (FA00) is set to enable communication command priority and
frequency priority, both priorities will be enabled unless OFF is set, power is turned off or is reset, or
standard shipment setting (  ) is selected. Emergency stop, RY terminal output hold and OUT
terminal output hold are always enabled even though communication command priority is not set.
Table 1 Data construction of communication commands (communication number: FA00)
bit Specifications
0 Preset speed operation
frequencies 1
1 Preset speed operation
frequencies 2
2 Preset speed operation
frequencies 3
3 Preset speed operation
frequencies 4
4 Motor selection (1 or 2)
(THR 2 selection)
5 PI control
6 Acceleration/deceleration
pattern selection (1 or 2)
(AD2 selection)
7 DC braking
8 Jog run
9 Forward/reverse
selection
10 Run/stop
11 Coast stop command
12 Emergency stop
13 Fault reset
14 Frequency priority selec-
tion
15 Command priority selec-
tion
Note: For the reset command, no data will be returned.
Ex.: Forward run: (PFA008400) CR
1 is specified for bit 15 (communication command: enabled) and bit 10 (operation command).
Ex.: Reverse run: (PFA008600) CR, (PFA00C600) CR
8600H : To disable frequency instructions from the computer
C600H : To enable also frequency instructions from the computer
0
Preset speed operation is disabled or
preset speed operation frequencies (1-
15) are set by specifying bits for preset
speed operation frequencies 1-4.
(0000: Preset speed operation OFF,
001-1111: Setting of preset speed
operation frequencies (1-15))
Motor 1
(THR 1)
Normal operation
Accelera-
tion/deceleration
tion/deceleration
pattern 1 (AD1)
pattern 2 (AD2)
OFF
Forced DC braking
OFF
run
Forward run
Stop
Standby
OFF
Emergency stop
OFF
OFF
OFF
BIT15
FA00:
1
0
0
0
8
1
S7 S9/nC1/S11
-
Motor2
(THR2)
-
PI OFF
Accelera-
Jog run
Reverse run
Run
Coast stop
Reset
Enabled
Enabled
0
1
0
0
0
0
0
4
0
44
Remarks
Preset speed operation can be
disabled or a preset speed op-
eration frequencies (1-15) can
be specified by combining 4 bits
variously.
THR1 : PT=set value, vL, vb, tHr
THR2 : PT=0, F170, F172, F173
AD1 : ACC, DEC,
AD2 : F500, F501
"E" trip
No data is returned from the
inverter.
Enabled regardless of the set-
ting of 
Enabled regardless of the set-
ting of 
BIT0
0
0
0
0
0
0
E6581222