Pipes A, A
, A
, A
, A
1
2
3
4
Combination unit
Unit model
Unit 1
Unit 2
P200YKB-A1
-
P250YKB-A1
-
P300YKB-A1
-
P350YKB-A1
-
P400YKB-A1
-
P450YKB-A1
-
P500YKB-A1
-
P400YSKB-A1
P200
P450YSKB-A1
P250
P500YSKB-A1
P250
P550YSKB-A1
P300
P600YSKB-A1
P350
P650YSKB-A1
P350
P700YSKB-A1
P350
P750YSKB-A1
P400
P800YSKB-A1
P450
P850YSKB-A1
P450
P900YSKB-A1
P450
P950YSKB-A1
P400
P1000YSKB-A1
P400
P1050YSKB-A1
P400
P1100YSKB-A1
P400
P1150YSKB-A1
P450
P1200YSKB-A1
P450
P1250YSKB-A1
P450
P1300YSKB-A1
P450
P1350YSKB-A1
P450
Pipes A, A
, A
, A
, A
1
2
3
4
Combination unit
Unit model
Unit 1
Unit 2
P200YKB-A1
-
P250YKB-A1
-
P300YKB-A1
-
P350YKB-A1
-
P400YKB-A1
-
P450YKB-A1
-
P500YKB-A1
-
P400YSKB-A1
P200
P450YSKB-A1
P250
P500YSKB-A1
P250
P550YSKB-A1
P300
P600YSKB-A1
P350
P650YSKB-A1
P350
P700YSKB-A1
P350
P750YSKB-A1
P400
P800YSKB-A1
P450
P850YSKB-A1
P450
P900YSKB-A1
P450
P950YSKB-A1
P400
P1000YSKB-A1
P400
P1050YSKB-A1
P400
P1100YSKB-A1
P400
P1150YSKB-A1
P450
P1200YSKB-A1
P450
P1250YSKB-A1
P450
P1300YSKB-A1
P450
P1350YSKB-A1
P450
*1 Use the ø12.7 (ø1/2) pipe if the piping length from the outdoor unit to the farthest indoor unit is 90 m (295 ft) or longer.
*2 Use the ø12.7 (ø1/2) pipe if the piping length from the outdoor unit to the farthest indoor unit is 40 m (131 ft) or longer.
*3 If the combination units 1, 2, and 3 are in a different order as listed in the table, make sure to use the pipes of appropriate size for the situation.
*4 If the pipe length after the first branching point exceeds 40 m (131 ft) (≤ 90 m (295 ft)), use the one size larger liquid pipe for all pipes from indoor
units to the first branch.
*5 When the vertical separation between the indoor units is 15 m (49 ft) (≤ 30 m (98 ft)), use the one size larger liquid pipe for all pipes from the
lower indoor units to the first branch.
KD79S703H01
Pipe A
Unit 3
Liquid
-
-
ø9.52
ø22.2
-
-
ø9.52*
ø22.2
1
-
-
ø9.52*
ø22.2
2
-
-
ø12.7
ø28.58
-
-
ø12.7
ø28.58
-
-
ø15.88
ø28.58
-
-
ø15.88
ø28.58
P200
-
ø12.7
ø28.58
P200
-
ø15.88
ø28.58
P250
-
ø15.88
ø28.58
P250
-
ø15.88
ø28.58
P250
-
ø15.88
ø28.58
P300
-
ø15.88
ø28.58
P350
-
ø19.05
ø34.93
P350
-
ø19.05
ø34.93
P350
-
ø19.05
ø34.93
P400
-
ø19.05
ø41.28
P450
-
ø19.05
ø41.28
P300
P250
ø19.05
ø41.28
P300
P300
ø19.05
ø41.28
P350
P300
ø19.05
ø41.28
P350
P350
ø19.05
ø41.28
P350
P350
ø19.05
ø41.28
P400
P350
ø19.05
ø41.28
P450
P350
ø19.05
ø41.28
P450
P400
ø19.05
ø41.28
P450
P450
ø19.05
ø41.28
Pipe A
Unit 3
Liquid
-
-
ø3/8
-
-
ø3/8*
1
-
-
ø3/8*
2
-
-
ø1/2
ø1-1/8
-
-
ø1/2
ø1-1/8
-
-
ø5/8
ø1-1/8
-
-
ø5/8
ø1-1/8
P200
-
ø1/2
ø1-1/8
P200
-
ø5/8
ø1-1/8
P250
-
ø5/8
ø1-1/8
P250
-
ø5/8
ø1-1/8
P250
-
ø5/8
ø1-1/8
P300
-
ø5/8
ø1-1/8
P350
-
ø3/4
ø1-3/8
P350
-
ø3/4
ø1-3/8
P350
-
ø3/4
ø1-3/8
P400
-
ø3/4
ø1-5/8
P450
-
ø3/4
ø1-5/8
P300
P250
ø3/4
ø1-5/8
P300
P300
ø3/4
ø1-5/8
P350
P300
ø3/4
ø1-5/8
P350
P350
ø3/4
ø1-5/8
P350
P350
ø3/4
ø1-5/8
P400
P350
ø3/4
ø1-5/8
P450
P350
ø3/4
ø1-5/8
P450
P400
ø3/4
ø1-5/8
P450
P450
ø3/4
ø1-5/8
Pipe A
*
3
1
Gas
Liquid
Gas
Liquid
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø9.52
ø22.2
ø9.52
ø9.52
ø22.2
ø9.52
ø9.52
ø22.2
ø9.52
ø12.7
ø22.2
ø9.52
ø12.7
ø28.58
ø9.52
ø15.88
ø28.58
ø9.52
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø12.7
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
ø15.88
ø28.58
ø15.88
Pipe A
*
3
1
Gas
Liquid
Gas
Liquid
ø7/8
-
-
ø7/8
-
-
ø7/8
-
-
-
-
-
-
-
-
-
-
ø3/8
ø7/8
ø3/8
ø7/8
ø3/8
ø7/8
ø1/2
ø7/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
GB-22
Pipe A
*
Pipe A
3
2
3
Gas
Liquid
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø22.2
-
ø22.2
-
ø22.2
-
ø22.2
-
ø22.2
-
ø22.2
-
ø28.58
-
ø28.58
-
ø28.58
-
ø28.58
-
ø28.58
-
ø22.2
ø12.7
ø22.2
ø22.2
ø12.7
ø22.2
ø28.58
ø12.7
ø22.2
ø28.58
ø12.7
ø28.58
ø28.58
ø15.88
ø28.58
ø28.58
ø15.88
ø28.58
ø28.58
ø15.88
ø28.58
ø28.58
ø15.88
ø28.58
ø28.58
ø15.88
ø28.58
Pipe A
*
Pipe A
3
2
3
Gas
Liquid
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø3/8
ø7/8
-
ø3/8
ø7/8
-
ø3/8
ø7/8
-
ø3/8
ø7/8
-
ø3/8
ø7/8
-
ø3/8
ø7/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø5/8
ø1-1/8
-
ø1/2
ø7/8
ø1/2
ø1/2
ø7/8
ø1/2
ø1/2
ø1-1/8
ø1/2
ø1/2
ø1-1/8
ø1/2
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
ø5/8
ø1-1/8
[mm]
*
Pipe A
3
4
Gas
Liquid
Gas
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
ø19.05
ø34.93
[in]
*
Pipe A
3
4
Gas
Liquid
Gas
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ø7/8
ø3/4
ø1-3/8
ø7/8
ø3/4
ø1-3/8
ø7/8
ø3/4
ø1-3/8
ø3/4
ø1-3/8
ø3/4
ø1-3/8
ø3/4
ø1-3/8
ø3/4
ø1-3/8
ø3/4
ø1-3/8
ø3/4
ø1-3/8