LG UBN24R Owner's Manual page 17

Table of Contents

Advertisement

Position of console Bolt
- A place where the unit will be leveled and
that can support the weight of the unit.
- A place where the unit can withstand its
vibration.
- A place where service can be easily
performed.
M10 Nut
M10 SP. washer
M10 washer
M10 washer
M10 SP. washer
M10 Nut
- Insert the set anchor and washer onto the
suspension bolts for locking the suspension
bolts on the ceiling.
- Mount the suspension bolts to the set
anchor firmly.
- Secure the installation plates onto the
suspension bolts (adjust level roughly) using
nuts, washers and spring washers.
Old building
1 Set anchor
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
bolts
• Local supply
① Set anchor
② Plate washer - M10
③ Spring washer - M10
④ Nut - W3/8 or M10
⑤ Suspension bolt - W3/8 or M10
X 4
• Tighten the nut and bolt top revent unit
(Local
X 4
supply)
X 4
X 4
(Local
X 4
1. Install declination of the indoor unit is
supply)
X 4
2. Minimum thickness of the insulation
New building
THE INDOOR UNIT INSTALLATION
CAUTION
!
falling.
CAUTION
!
very important for the drain of the duct
type airconditioner.
for the connecting pipe shall be 10
mm.
Safety drain hole
Main drain hole
Drainage hole
17
Drainage hole