Other Information - Samsung SSA-S2000V User Manual

Standalone rfid access controller
Table of Contents

Advertisement

other information

INITIAL VALUES
This product operates in the following initial values:
For changing the settings or registering/deleting the user card, refer to the applicable section in this document.
1)
Entry permitted for a registered card
- The door control relay operates for 3 seconds.
- The green LED indicator fl ashes for 3 seconds.
2)
Entry denied for an unregistered card
- The alarm relay operates for 2 seconds.
- The red LED indicator fl ashes for 2 seconds.
3)
Duress Mode Password : 00
The TTL output port produces a signal for 3 seconds in Duress mode.
4)
QUICK MODE : Disabled
5)
Chime Bell Output : Enabled
Chime Bell Operating Time : 0.5 second
6)
Melody Sound : Enabled
7)
Keypad Input Limited Use : 20 seconds
8)
When an input signal is sensed : 'H'
9)
When a TTL output signal is sensed : 'H
10)
Patrol Mode Delay Time : 00 minute
11)
Door Sensor Sensing Time : 00 second
12)
Retry count for an unauthenticated entry : 05 times
13)
Alarm for Dismantled Device : Disabled
Dismantled device Alarm Output Port : 02 (Alarm Relay)
14)
Toggle Mode : Disabled
15)
Control Lock by the Door Sensor : Disabled
'L' (common for all inputs)
L'
English _ 41