QUICK START GUIDE
 
FILLING SOLUTION TANK
1.
Open the water inlet cover (A, Figure 11).
2.
Fill with water or solution suitable for work performance through the water inlet
with filter.
The solution temperature must not exceed +104F (+40°C).
3.
Do not overfill the tank, refer to water level indicator (D) for the water volume.
WARNING!
Use only low-foam and non-flammable detergents, intended
for automatic scrubber applications.
DRIVE MOTOR AND MECHANICAL BRAKE INSPEC-
TION
1.
Turn the ignition key (A, Figure 12) to "I", sit on the seat (C).
2.
Depress the accelerate pedal (D) slightly then release it to check if the ma-
chine can be steered forward and stopped.
3.
To ensure safety, confirm the machine can be stopped immediately when
pressing the emergency button (B). Rotate the emergency button to reset it.
4.
Depress the mechanical brake pedal (F) quickly to check if the machine can
be stopped immediately.
WARNING!
Working climbing capacity shall not exceed 16%. When
working on slope, must keep the tank latches (7, Figure 1)
engaged. For safety, never stop it on slope.
CAUTION
The brake of drive motor is released when the motor works
normally, it locks when the motor is off. In some special
cases, such as machine packing/unpacking, machine fault
etc., the machine may need to be pushed. On drive motor
(G, Figure 12) push down the brake handle (H, Figure 12),
the machine brake is released, and the machine can be
moved. After completion, push up the handle back, so the
machine can work.
MACHINE START AND STOP
Start the machine
1.
Prepare the machine as shown in the previous paragraph.
2.
Sit on the seat (K, Figure 13), insert the Ignition key (J, Figure 13) and turn it to "I". Check batteries status from display screen. If
necessary to charge the batteries (see the procedure in Maintenance chapter).
3.
Drive the machine to the working area.
The forward/reverse direction can be controlled with the switch (H, Figure 13). The speed can be adjusted with the adjuster (E, Figure
13).
4.
Press One-Start button (G, Figure 13) to start the machine, the squeegee and brushes are lowered to the floor automatically, and
the vacuum motor begins to work.
5.
Press the solution flow control buttons (F, Figure 13) as necessary, depending on the type of cleaning to be performed.
6.
Depress the accelerator pedal (Q, Figure 13), and start cleaning.
7.
You can charge your phone or pad through USB charging port (M, Figure 13) when the Ignition key (J, Figure 13) is turned to "I".
8.
Press the horn button (B, Figure 13) to warn people when necessary.