Dear Customer, thank you for purchasing a MASTER S.p.A. product. This guide contains all the information you will need concerning the use of this product. Read the instructions
carefully and keep them for further consultation. The module X60 EGO is specially designed for the control of a tubular motor with
field defined by MASTER S.p.A. is forbidden. This, as well as the breach of the instructions given in this guide, shall release MASTER S.p.A. from any liability and shall annul the product
warranty.
Technical specifications
ü
Power supply :
120 o 230 Vac 50/60 Hz
ü
Contact capacity :
7 A@250 Vac
ü
Grade of protection :
IP20
ü
Working time :
from 1 to 250 s
01. WARNINGS
01.1 Warnings for safety
Incorrect installation can cause serious injuries
and maintenance operations must be carried out only by a qualified and skilled technician, who must comply with laws, provisions, local regulations and the instructions given on this
manual
The electrical wiring must comply with current IEC standards
particular safety devices
To prevent potentially dangerous situations, check the operating condition of the roller shutter/awning regularly
01.2 Warnings for installation
Adjust the limit switches of the motor before connecting it to the module
unsuitable tools can cause damage
sight of the roller shutter/awning but a long way from its moving parts. Position the buttons more than 1.5 m from the floor
The module does not provide any protection against water and only essential protection for contact with solids
sources of heat and near metal surface
01.3 Warnings for use
The product is not intended for use of persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised
or given instructions on how to use the product by a person responsible for their safety
involved in its movement. Check the automation during the movement and keep people at a safe distance, until the movement ends
with the fixed control devices. Furthermore, keep the portable control devices (remote controls) out of reach of children
operations are being carried out (e.g. window cleaning). If the control device is automatic, disconnect the motor from the power line
02. ELECTRICAL CONNECTION
Make connections with power supply disconnected
breaker. The installer must fit an isolation device (with 3,5 mm minimum opening on the contacts) upstream of the system
or short circuits. You must provide, on the supply line, an adequate protection to the load, for example a fuse of maximum value 3,15 A
proportionate to their length and to the absorption of the load, and in any case not less than 1,5 mm
Command buttons are connected to the main voltage, so they must be properly insulated and protected
02.1 Power supply
The module can be powered at 120 Vac or 230 Vac. The supply voltage must be applied to terminals and
02.2 Connecting the motor
The motor windings must be connected to the terminals and , the common wire of the motor must be connected to terminal .
the module. If it is necessary to connect more than one motor to the module use the appropriate expansion cards.
02.3 Connecting the S single commands buttons
The single command buttons must be connected to terminals 5 and 6, the common thread of the buttons must be connected to terminal 1. The command buttons are subject to the mains
voltage and therefore must be properly insulated and protected. You must use momentary (hold-to-run) button, do not use buttons with maintained position. More than one command
button can be connected to the unit through a parallel connection. For the correct operation of the system it is necessary to check that the closure of the button connected to terminal 6 (
S, up single) matches the upward movement of the motor, if not, invert the wires of the motor windings to the terminals 7 and 8.
02.4 Connecting the G general commands buttons
The general command buttons must be connected to terminals
maintained position. More general command buttons can be connected via a parallel connection.
GENERAL
Command
L
N
POWER SUPPLY
3. OPERATING LOGIC OF THE BUTTONS
Single and general command buttons can operate in two different operating logics: "impulse" mode or "hold-to-run" mode. The procedure to select the operating logic of the buttons is
described in Section 4.4 ("selection of the operating logic of the buttons"). The factory sets the buttons in the "impulse" mode.
"Impulse" mode: to perform a single command up or down, press the corresponding button for at least 0.5 seconds, to stop the manoeuvre briefly press any of the command buttons
(single or general). To perform a general command up or down, press the corresponding button for at least 0.5 seconds, to stop the manoeuvre briefly press any of the command buttons
(single or general). The upward and downward general manoeuvres will be performed in compliance with the switch-on delay, as explained in section 4.2 ("insertion delay on the general
command").
"Hold-to-run" mode: to perform a single or general command, up or down, press the corresponding button, the operation will stop when the button is released. If the buttons work in this
logic the "insertion delay on the general command" function and the "air change" function are not available.
R
User manual:
ü
Dimensions :
ü
Working temperature :
Keep these instructions for future maintenance work and disposal of the product
Do not pierce or tamper with the box in any way. Do not modify or replace parts without the manufacturer's permission
For your safety, do not work near the winding roller while the motor is powered
Check that the power supply does not depend from electrical circuits for lighting
7
8
3
and
e
G O
MAX 7A
X60
120-230V
230V
50-60Hz
L
N
M
G
G
S
S
1
2
3
4
5
6
7
Fuse
3,15A max
X60
44 x 38 x 25 mm
-20°C / +55°C
Some applications require «hold-to-run» operations and can exclude the use of radio controls or require
Check that the package is intact and has not suffered damages in transit
Before operating on the roller shutter/awning, make sure there are no people or objects in the area
Use momentary (hold-to-run) control buttons.
You cannot connect more than one motor directly to the module.
1
2.
4
and must close on terminal 1. You must use momentary (hold-to-run) button, do not use buttons with
8
manoeuvre 1
Fuse
3,15A max
manoeuvre 2
SINGLE
command
e
G O
mechanical limit switches
Disposal!!
At the end of the product life cycle, dispose of the device in
compliance with local regulations. This product could contain
substances that are harmful to human health and the
environment: do not dispose of the product in domestic waste.
All the product installation, connection, programming
The product is designed to be inserted inside of junction boxes.
It is forbidden to install the module in areas not adequately protected, near
Do not allow children to play with the appliance or
Do not operate on the roller shutter/awning when maintenance
The supply line must be equipped with a circuit
The product doesn't provide any protection against overloads
The section of the connecting cables must be
1 You can not connect more than one motor directly to
e
G O
MAX 7A
X60
120-230V
230V
50-60Hz
L
N
M
G
G
S
S
1
2
3
4
5
6
7
8
manoeuvre 1
manoeuvre 2
rev03_29.07.16
. All other use beyond the
A heavy knock and the use of
Position the buttons withing
Do NOT use stay-put switches
SINGLE
command