Technical Data; Gas Pressure - Wolf CG Series Service Manual

Hide thumbs Also See for CG Series:
Table of Contents

Advertisement

Technical Data

TECHNICAL DATA
GAS PRESSURE REFERENCE

GAS PRESSURE

Pressure
Natural gas and liquid propane
maximum
Gas supply
Natural gas minimum
line pressure
Liquid propane minimum
Natural gas manifold pressure, with standard
orifice
Liquid propane manifold pressure, with standard
orifice
824779 REV. C
CG Series Gas Cooktops Service Manual
Part
Description
Value
Burner valve,
14" WC
18 K, Nat.
Burner valve,
7" WC
18 K, LP
11" WC
Burner valve,
5" WC
12 K, Nat.
10" WC
Burner valve,
12 K, LP
Burner valve,
9.2 K, Nat.
Burner valve,
9.2 K, LP
Orifice
holder, 20 K,
Nat.
Orifice
holder, 20 K,
LP
Orifice
holder, 18 K,
Nat.
Orifice
holder, 18 K,
LP
Orifice
holder, 12 K,
Nat.
Orifice
holder, 12 K,
LP
Orifice
holder, 9.2 K,
Nat.
Orifice
holder, 9.2 K,
LP
Note: Natural gas units installed over 9,900 feet may require a high
altitude conversion kit.
8
service.subzero.com
ORIFICE QUICK REFERENCE CHART
Part
Orifice Size
Number
Part Number
Simmer
817308
9017243
Main
819770
Simmer
816465
9017244
Main
816465
Simmer
816788
9017241
Main
816731
Simmer
816538
9017242
Main
817372
Simmer
816788
9017239
Main
816610
Simmer
816538
9017240
Main
816823
Simmer
817193
826443
Main
824936
Simmer
817192
826444
Main
824937
Simmer
817193
823061
Main
824936
Simmer
817192
823074
Main
824937
Simmer
816749
819299
Main
816750
Simmer
817192
824288
Main
819768
Simmer
816749
819297
Main
816664
Simmer
817371
819298
Main
817370
Stamped
MM
62
.79 mm
67
.67 mm
43
.43 mm
43
.43 mm
50
.50 mm
57
.57 mm
33
.33 mm
38
.38 mm
50
.50 mm
54
.54 mm
33
.33 mm
34
.34 mm
79
.79 mm
2.05
205
mm
47
.79 mm
2.05
132
mm
79
.79 mm
2.05
205
mm
47
.47 mm
1.35
132
mm
65
.65 mm
1.59
159
mm
47
.47 mm
1.05
105
mm
65
.65 mm
1.40
140
mm
41
.41 mm
93
.93 mm