The fan units which Woods Air Movement supplies are of the utmost modernity and meet all safety regulations of the EC machine guideline 2006/42/EC, EMC guideline 2006/95/EC/EG and low voltage guideline 2004/108/EC.
4. GENERAL SAFETY PRECAUTIONS - Always read through these safety instructions with care and be sure to follow them, - electricity must be turned off before you can begin cleaning or maintenance work (see Point 8), - maintenance work on the fan unit must be carried out by a technically qualified professional, contact the supplier to do so, - safety precautions have been created for each operation, such as;...
5. TRANSPORT 5.1. TRANSPORT DAMAGE You must immediately check the shipment to make sure it is undamaged and complete and must do so in the presence of the supplier. In the case of transport damage, contact the service department for advice (see contents).
6. ASSEMBLY / INSTALLATION 6.1. SAFETY PRECAUTIONS - Assembly may be carried out only by technically qualified personnel, whereby this manual and the applicable specifications must be adhered to. - Assemble the unit with the correct locking/torque wrench. - Check the 4 mounting points with which the fan is secured to the ceiling/wall. - Safety guards and similar which are disassembled for installation must be immediately returned to their proper position after installation and before reconnection to the power supply.
Page 9
6.3.3 MOTOR PROTECTION Fuses and contact breakers do not suffice as motor protection. The manufacturer’s guarantee becomes void in the case of damage as a result of insufficient motor protection. The EC motor protection is integrated in the motor electronics, be sure that in case a fault occurs, the EC motor can not switch on again automatically after it has cooled down.
Page 10
7. IMPLEMENTATION 7.1. SAFETY CHECK Check to see that all mechanisms and electrical protections are in place and connected. The following checks must be made before the unit can be switched on: Make sure that an uncontrolled start-up of the fan unit during implementation is impossible (such as with a lockable work switch)! 7.1.2.
7.2.1 FIRST STARTING CHECK-UP / COMMISSIONING REPORT - After the unit is switched on, the motors start an initialization, after a few seconds of the initialization the control input is active. The unit can be switched on via the control input. Do the commissioning tests at maximum speed, as soon as the commissioning tests are done switch off the unit via the control input.
8. MAINTENANCE AND REPAIRS 8.1. SAFETY PRECAUTIONS Maintenance personnel will be faced with danger of personal (fatal) injury if these precautions are not complied with. Maintenance and repairs may be carried out only by technically qualified personnel, whereby this manual and the applicable specifications must be adhered to.
Page 13
- Screw tightness in general (of unit, motor, service switch, etc…) - Winding life of the motor - Insulation resistance - Drain condensed water, etc. Woods Air Movement bears no liability for damage arising as a result of the use of components which have not been supplied through the manufacturer.
9. OPERATIONAL FAILURE Deviations from the fan unit’s normal operating condition (noise, vibrations, smoke, current strength) indicate a fault in the fan unit and must be investigated immediately by maintenance personnel. Long-term faults can lead to serious damage to the fan unit and installation components and can result in personal injury! If the maintenance personnel are unable to remedy the fault, you must contact the fan’s supplier.
10. CONNECTION DIAGRAM Attachment: Technical Specifications Sheet. EC-ITF A. Connection diagram OTB – Power supply/Control Interface Power supply 200~240/1/50/60 P11 = L Fan motor 1 &2 P12 = N P13 = Earth -------------------------------------------------- --------------------------------------------------- Control interface P21 = 10 Volt fan 1 P22 = 0-10 Volt fan 1 &...
11. CE & UKCA MARKING 11.1 Declaration of Conformity We hereby declare under our sole responsibility that Woods Air Movement products comply with the requirements of the applicable UK and EC/EU directives. The Declaration of Conformity for compliance with the applicable directives exclusively refers to fans that are connected according to the operating instructions and operated independently with sinusoidal power supply.
Page 17
The specific documentation will be transmitted to the official authorities on justified request through electronic means, on data carriers or on paper.Name of representative for documentation: Address of the nominated Person: see manufactures address EC-declaration of Incorporation was issued: Place, Date Colchester, 10.10.2019 Simon Chapman R&D Director Woods Air Movement...
Page 18
Woods Air Movement delivers smart and energy efficient Air Movement and Fire Safety solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than fifty years of accumulated industry application experience.