Advertisement

Quick Links

CLEANLOAD NEXUS
COUPLER FOR CLOSED TRANSFER WITH EASYCONNECT CAPS
P/N: PNR-CN100
INSTALLATION AND OPERATING MANUAL
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.

Advertisement

Table of Contents
loading

Summary of Contents for Pentair HYPRO CLEANLOAD NEXUS

  • Page 1 CLEANLOAD NEXUS COUPLER FOR CLOSED TRANSFER WITH EASYCONNECT CAPS P/N: PNR-CN100 INSTALLATION AND OPERATING MANUAL PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 2 CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 3: Table Of Contents

    7.4 .... Inspection and replacement of Umbrella Valves ........................21 8..OPERATING HANDLE FUNCTIONS .............................23 9..TROUBLESHOOTING ..................................24 9.1 .... Fault recording sheet ................................25 10..SPARE PARTS LIST ..................................26 11..WARRANTY ....................................27 PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 4: Safety Information

    3. Before attempting to carry out any maintenance or repair, make agrochemical label. sure that you are wearing appropriate PPE. specific required agrochemical label wear gloves, protective glasses and a chemical resistant apron or overall when operating, maintaining servicing Cleanload Nexus. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 5: Layout & Parts Included

    (Section 7.1) Qty. 1 P/N: PNR-CN100-OIPM CLEANLOAD NEXUS Operating Installation COUPLER FOR CLOSED TRANSFER WITH EASYCONNECT CAPS P/N: PNR-CN100 INSTALLATION AND Manual OPERATION MANUAL Qty. 1 PNR-CN100-OIPM (09/27/21) ©2021 Pentair. All Rights. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 6: Specification

    Misuse: Any other uses are considered misuses and are prohibited. Contact ∙ DO NOT operate with packaging that has not been factory fitted Pentair or your local sprayer service agent with any questions with easyconnect caps. regarding specific acceptable uses.
  • Page 7: Installation

    Avoid low points in If mounting Cleanload Nexus permanently on CAUTION the Suction hose where residue could collect. the sprayer, ensure that it is protected against mud, dust and impact from branches, machinery etc. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 8: Cleanload Nexus Plumbing Layout

    If Cleanload Nexus is not mounted correctly, it may WARNING and the Rinse Water Supply Hose can be permanently plumbed into result in malfunctioning, spillage of agrochemical and contamina- the sprayer. tion of the operator and/or environment. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 9: Connecting The Suction Hose

    These connectors are not included. To CLEANLOAD NEXUS 1" Hosetail connector 2 Calibrated part of hose Female dry break connector 3 Check valve Male dry break connector 4 Hose clamp To sprayer suction PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 10: Connecting The Rinse Water Supply Hose

    DO NOT operate the Rinse Water Lever at this stage. Nexus are closed and no air or liquid movement can occur. The suction must always be turned on and WARNING drawing from the Cleanload Nexus before a container is attached. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 11: To Secure A Container To Cleanload Nexus

    Remove the dust cover from the easyconnect cap.. Check that the tamper evident strip is also fully removed from the bottle. Visually check that the easyconnect inner plug is in WARNING place (but do not push it!). PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 12: Procedure For Partially Emptying A Container

    For advice on what to do if the plug on the easyconnect cap becomes dislodged from the probe during measuring see Section 9 (8; easyconnect cap) on page 24. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 13 As the liquid approaches the desired calibration mark, move the handle back to the left. The flow stops when the handle passes the beginning of the measuring zone. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 14 The Rinse Water Lever should turn and engage CAUTION smoothly. If it does not, then check the Operating Handle is aligned with the Lock Release Knob. Never attempt to force the Rinse Water Lever. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 15 Replace the Top Cover (Ref 16) onto the Cleanload Nexus before beginning spraying operations. The remaining contents of the partially used container can be used in the future with Cleanload Nexus, in the same way as a new container. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 16: Procedure For Completely Emptying A Container

    The Rinse Water Lever should turn and engage CAUTION smoothly. If it does not, then check the Operating Handle is fully to the right. Never attempt to force the Rinse Water Lever. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 17 Once the container is empty and clean, move the Operating Handle (Ref. 11) back to the Lock Release Knob (Ref. 12), when you will hear it engage and it will not rotate any further. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 18 Lever. Repeat 3 more times for a total of 40 seconds for optimum rinsing. Only rotate the container in a clockwise direction. CAUTION Never rotate the container anti-clockwise or the CAUTION easyconnect cap may become loose. 1 - 4 10 seconds at each position. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 19 If this is the last container, ensure that the Cleanload Nexus cleaning procedure (in section 7.1) is completed. Replace the Top Cover (Ref 16) onto the Cleanload Nexus before beginning spraying operations. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 20: Cleaning & Maintenance

    Hosetail Outlet (Ref. 6) and store / dispose of in accordance with guidelines. When storing Cleanload Nexus: ∙ Ensure that it is secure and inaccessible to children and animals. ∙ It is always stored in frost free conditions. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 21: Maintenance Of Cleanload Nexus

    If you are in any doubt about the reason for loss of the Umbrella Valves or how to carry out this replacement procedure consult a Cleanload Nexus service agent. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 22 After screwing the screws back, rotate the handle back to the start position to finish the procedure. If you have any concerns about effective operation, for service, spare parts and service advice contact your sprayer dealer or service agent. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 23: Operating Handle Functions

    SUCTION CLOSED SUCTION CLOSED 25° 110° CONTAINER SECURE SUCTION OPENS PROGRESSIVELY FROM HERE SUCTION CLOSED 30° 160° CAP RINSE SUCTION FULLY OPEN SUCTION OPEN 185° 50° CONTAINER RINSE POSITION SUCTION CLOSED SUCTION OPEN PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 24: Troubleshooting

    Nexus invert both the Cleanload Nexus and the container to drain the contents back into the rinse water is seen to entered the container container which can then be carefully removed. enter the container. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 25: Fault Recording Sheet

    9.1 Fault recording sheet Use this sheet to mark and describe any faults you experience and send it to your Cleanload Nexus Service Agent. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...
  • Page 26: Spare Parts List

    CTS Mounting Kit. Stand or bracket for mounting off sprayer (if required). P/N: 2420-0034SP Top Cover CTS. P/N: 2420-0054SP Top Cover String CTS. Crimping tool for securing ear clamps. P/N: PNRNEX-KITSER Service Kit. CLEANLOAD NEXUS PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
  • Page 27: Warranty

    Where products are found not to be defective (under the terms of this limited warranty), then the Buyer must pay return packing and freight charges. Where products are tested and found to be covered by this limited warranty, then Pentair will pay for return packing and freight charges.
  • Page 28 *Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous material being shipped. Failure to do so may result in a substantial fine and/or prison term. Check with your shipping company for specific instructions. PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights. CLEANLOAD NEXUS...

This manual is also suitable for: