ADJUSTMENT (TUNER)
< TUNER SECTION >
2. MW VT Adjustment
Settings : • Test point :
• Adjustment location : L953
Method : Set to MW 1710kHz and adjust L953 so that the test
point becomes 8.5V ± 0.05V. Then set to MW 530kHz
and check that the test point is more than 0.3V.