4

SPECIFICATIONS

Service Ref.
Power source (Phase, cycle, voltage)
Max. current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan (drive) × No.
Fan motor output
Airflow
Defrost method
Noise level
ATA Cooling
HR Cooling
TA Heating
ATW Heating
Dimensions
W
D
H
Weight
Refrigerant
Charge
Oil (Model)
Pipe size
ATA
Liquid
O.D.
Gas
ATW
Liquid
Gas
Connection method
ATA indoor side
ATW indoor side
Outdoor side
Between the indoor &
Height difference
outdoor
Piping length
OCH665B
A
kW
W
kW
K/min (CFM)
dB
dB
mm (inch)
mm (inch)
mm (inch)
kg(lb)
kg(lb)
L
mm (inch)
mm (inch)
mm (inch)
mm (inch)
PUHZ-FRP71VHA2
PUHZ-FRP71VHA2R1
Single, 50 Hz, 230 V
19
Munsell 3Y 7.8/1.1
Linear Expansion Valve
Hermetic
SNB172FSHM1
1.6
Inverter
HP switch
Comp. surface thermo
Discharge thermo
Plate fin coil
Propeller fan x 1
0.086
50 (1,760)
Reverse cycle
47
49
950 (37-3/8)
330+25 (13-7/8)
943 (37-1/8)
73 (161)
R410A
3.8 (8.4)
0.70 (FV50S)
9.52 (3/8)
15.88 (5/8)
9.52 (3/8)
15.88 (5/8)
Flared
Flared
Flared
Maximum 20 m
Maximum 60 m total, Maximum 30 m for each
8