PHENOMENON
After connecting the power
and pressing the "Power"
key, the appliance has no
response
Induction Cooker send out
"Beep" Sound
No Operation during the
heating being in use
Error codes occur E0
Error Codes occur E1
Error Codes occur E2
Error Codes occur E3
Error Codes occur E4
Error Codes occur E5
Error Codes occur E6
Error Codes occur E7
If the above remedies/controls cannot
fix the problem, unplug the appliance
immediately, contact service center
for inspection and repairing, note the
error code and report it to service
center ltd. To avoid any danger and
damage to the appliance, do not dis-
assemble or repair it by yourself.
CHECK POINTS
Is the electricity in sus-
pension?
Is the plug connected
firmly?
Is the fuse broken down?
Incompatible cookware or
no cookware is used?
Is the cookware not con-
siderably placed from the
center of the heating
zone?
Is the cookware bigger
than 12cm?
Is the cookware empty or
the temperature too high?
Is the air intake/exhaust
vent clogged or dirt has
accumulated
Without Cookware or In-
compatible cookware used
Low-Voltage
High-Voltage
Top plate Overheat
Top Plate Sensor Open
Circuit
IGBT Overheat
Top Plate Sensor Short
Circuit
Internal circuit error

SPECIFICATIONS

Power:
Rated voltage:
Rated frequency:
Rated current:
Net weigh:
Gross weight:
6
REMEDY
Use after resuming the
electricity
Check the root causes
carefully. If the problem
can't be fixed, please con-
tact service center for
checking and repairing.
Replace compatible
cookware for the induction
cooker
Replace the cookware at
the center of the defined
heating zone.
Change the diameter of
cookware bigger than
12cm
Please check whether the
appliance is being misused
Remove the stuff clogging
the air intake/exhaust
vent. Operate the appli-
ance again after cooling
down.
When showing error signal
E0, E3, E5, please check
whether the cookware is
not suitable, or switch on
the appliance again after it
is cooled down naturally.
When showing E1, E2, E4,
E6, E7, please contact
service center for checking
and repairing.
2000W
220 V
50 Hz
9.1 A
1.65 kg
1.95 kg