Front Panel
Message
Full Name
LOOPBACK MESSAGES
CLOC
Customer Local Loopback
COLB
Central Office Loopback
CREM
Customer Remote Loopback
NLOC
Network Local Loopback
NREM
Network Remote Loopback
RULB
Remote Unit Loopback
SMJK
Remote SmartJack Loopback
DIAGNOSTIC MESSAGES
A = xx
Maximum Loop Attenuation
ACQ
Acquisition
ARM
HiGain System Armed
BAD RT?
No Response from H2TU-R
BAD RGND
H2TU-R Frame Ground Signal
FERR
Framing Bit Error Occurred
HES
HDSL2 CRC Error
LBPV
Local Bipolar Violation
M=xx
HDSL2 Loop Margin
PWR FEED OFF
Power Feed Off
PWR FEED ON
Power Feed On
SIG
Signaling
SYSTEM INFORMATION MESSAGES
VER x.xx
Software Version Number
LIST xx
List Number
FRM xxxx
Frame: SF, ESF, UNFR, or AUTO
CODE xxxx
Line Code: AMI or B8ZS
LATT xx
Loop Attenuation
MARG xx
Margin
(a) System information messages are displayed in Scroll Mode. To scroll through the messages, press the MODE pushbutton for
3 or more seconds. After system information messages scroll, the front panel displays the line card options (see
page 16
and
Table 6 on page
6
Table 2. Front-Panel Display Messages (Continued)
Description
Signal from customer is looped back to the customer at the H2TU-R.
Dual loopback at the H2TU-C.
Signal from customer is looped back to the customer at H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-C.
DSX-1 signal is looped back to the network at the H2TU-R.
Dual loopback at the H2TU-R.
DSX-1 signal is looped back to the network at the H2TU-R SmartJack
module.
The Attenuation (A) message appears followed by xx, where xx is the
loop attenuation of the longest (maximum loss) span, measured in dB.
The multiplexers of the H2TU-C and H2TU-R (or the H2TU-C and first
regenerator) are trying to establish synchronization over the HDSL2 loop
of Span 1.
Armed to respond to Intelligent Repeater Loop (ILR) codes.
The H2TU-C receives no response from the H2TU-R and all HDSL2 loop
conditions are normal. Therefore, the integrity of the H2TU-R or the
HDSL2 loop is questionable.
The H2TU-R does not have a frame ground connection.
Framing bit error has occurred at H2TU-C DSX-1 input.
H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.
A bipolar violation has been received at the DSX-1 input to the H2TU-C.
Indicates the power of the received HDSL2 signal relative to noise (signal
to noise with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation.
HDSL2 span power has been turned off by setting the PWFD option to
off, or HDSL2 span power has been turned off by use of the A2LB
Intelligent Office Repeater (IOR) Power Down code.
Indicates that the HDSL2 loop is not grounded or shorted.
The transceivers of the H2TU-C and H2TU-R are trying to establish
contact with each other over the HDSL2 loop of Span 1.
(a)
The software version number of the H2TU-C.
The list number of the H2TU-C.
Defines the type of frame pattern being received from the DSX-1:
SuperFrame (SF), Extended SuperFrame (ESF), Unframed (UNFR), or
AUTO.
The DS1 line code setting: Alternate Mark Inversion (AMI) or Bipolar with
8-Zero Substitution (B8ZS).
The current loop attenuation threshold setting measured in decibels.
The current margin threshold setting measured in decibels.