FinsGateway Modem Module User's Manual
FinsGateway
FinsGateway
FinsGateway
FinsGateway
Modem Module
Modem Module
Modem Module
Modem Module
User' ' ' ' s Manual
User
User
User
© © © © Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
Copyright OMRON Corporation 1999 All Rights Reserved
s Manual
s Manual
s Manual
OMRON Corporation
Page: 1
First Version
November, 1999

Advertisement

Table of Contents
loading

Summary of Contents for Omron FinsGateway

  • Page 1 Manual First Version November, 1999 OMRON Corporation © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 2: Table Of Contents

    ......©Copyright OMRON Corporation 1995,1996-1998,1999 All Rights Reserved. FinsGateway was developed using Microsoft Visual C++ Version 5.0 and Version 4.1, Borland Delphi Version 2.0, and Microsoft FrontPage98. Copyrights of the FinsGateway manual and software are owned by OMRON Corporation, except the following items.
  • Page 3 Page: 3 FinsGateway Modem Module User’s Manual 1 Introduction The Modem Module is an add-on software for FinsGateway remote communication. You can develop a remote PLC data acquisition application quickly and easily using the modem module. Analog Phone Line FinsGateway + Modem Module ©...
  • Page 4 Page: 4 FinsGateway Modem Module User’s Manual 2 System Requirements The Modem Module is an add-on software for FinsGateway. Therefore, the environment must support the operation of FinsGateway. The following system specifications are recommended to operate the Modem Module. © © © © Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 5: Setting The Plc Modem

    AT command to the PLC. modem. © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 6 FinsGateway Modem Module User’s Manual 1. Plug the PLC modem into the COM port of the computer. 2. Click on the Start button, point to Programs, point to FinsGateway, and point to PLC Modem Setup. 3. Select the COM port for the modem in the COM port box.
  • Page 7: Serial Communications Driver Settings

    3 – 2 Serial Communications Driver Settings 1. Exit PLC Reporter if it is running. 2. Click on the Start button, point to Programs, point to FinsGateway, and point to Serial Communications Setup. 3. Click the Communications Line tab and select the check box of the COM port for the modem to add the phone line.
  • Page 8: Registering Telephone Numbers

    4 – 1 Registering Telephone Numbers 1. FgwTapiCaller Settings Click on the Start button, point to Programs, point to FinsGateway, and point to FgwTapiCaller. 2. Select Phone Line Type Click on the Dialing Properties button. Select Tone dialing or Pulse dialing in the Dialing Properties dialog to set the dialing type.
  • Page 9 7. Click [OK] to finish the telephone number setup. Click [cancel] to cancel the settings and quit. © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 10: Serial Communications Driver Settings

    Click the icon to see the dialog again. © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 11: Close The Line

    You can also close the line by clicking on the Disconnect button in the line status dialog. Close the line manually. © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 12: 5 5 5 Caution Caution

    Modem - PLC 19200 bps 33600 bps 9600 bps © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 13: Connecting The Plc Modem

    Flow control or the CD/DR/ER signal control settings may be required for the modem. See the modem manual and determine the AT commands to set them. © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...
  • Page 14: 6 6 6 Troubleshooting Troubleshooting

    Confirm that the modem is connected to the right COM port. Confirm that the COM port for the internal modem matches the settings. © © © © Copyright OMRON Corporation 1999 All Rights Reserved Copyright OMRON Corporation 1999 All Rights Reserved...