Introduction & company profile INTRODUCTION Thank you for choosing our product! The NEMTEK Druid LCD 20 fence monitoring system is designed and manufactured to provide many years of reliable use, if installed and maintained correctly. The guidelines provided in this manual will assist you with the basic operation and maintenance of your unit.
NEMTEK does not guarantee that the operation of the product will be uninterrupted and totally error free. Faulty units must be returned to one of the NEMTEK Group outlets. The buyer shall pay all shipping and other charges for the return of the product to NEMTEK or NEMTEK Security Warehouse.
Foreword The DRUID LCD 20 should ideally be operated by means of a remote keypad to obtain access to the many monitoring features and receive the greatest protection. It can however be operated by means of a NEMTEK tab or external switch.
Symbol interpretation Fence or Gate alarm condition present: Fence or Gate alarm history (occurred in the past): Fence or Gate alarm bypassed: Gate is open: Gate alarm immediate (alarm will sound the moment the gate is opened): Mains power present: Mains fail history (occurred in the past): Mains power fail with internal battery condition GOOD: , LOW:...
Symbol to descriptive label link A symbol shown on the LCD (Liquid Crystal Display), depending on its position, is linked through one of the eight linking lines above the LCD to one of eight descriptive labels. A brief interpretation of the symbol displayed on the LCD is to be found under the descriptive label it is linked to.
Unless this feature has been disabled by the installer, the unit can be activated or deactivated by presenting the NEMTEK plastic tab over the corresponding logo on the fascia of the unit. Remove the tab when the unit produces a short beep, after which the unit will toggle its operating state.
Operation with a keypad The unit may be operated by up to two keypads. In this case the NEMTEK tab becomes optional (Installer programmable feature). In order to provide different access levels to the unit and its functions, two different types of users are defined.
Using your keypad All keypad codes must end with the # key to enter the code sequence. If you pause for more than five seconds between key presses, the keypad will produce a fast beeping sequence and all earlier keys will be deleted. A correctly entered sequence will be acknowledged with two beeps.
Page 12
Using your keypad MASTER PIN FENCE ALARM BYPASS _ _ _ _ * 2 1 # (alarm bypassed) MASTER PIN _ _ _ _ * 2 0 # (alarm not bypassed) Use this feature to prevent the alarm from sounding when a fence fault occurs. Typically you would not want to bypass the fence alarm, however this feature is available should it be needed.
Page 13
Using your keypad MASTER PIN GATE ALARM BYPASS _ _ _ _ * 4 1 # (gate alarm bypassed) MASTER PIN _ _ _ _ * 4 0 # (gate alarm not bypassed) Use this feature to prevent the alarm from sounding when the gate is open for longer than the gate delay time.
Page 14
Using your keypad MASTER PIN SERVICE ALARM BYPASS _ _ _ _ * * 1 # (bypassed) MASTER PIN _ _ _ _ * * 0 # (not bypassed) Use this feature to prevent the alarm from sounding when a service condition exists. A service condition may occur for a short duration after a prolonged mains power failure.
Page 15
Using your keypad DISPLAY INFORMATION 6 ? # Replace the ? above with the required digit for the information you want displayed as listed below. • GOOD, CHECK, BAD 6 0 # This is the default display as shipped from the factory and shows the words GOOD, CHECK or BAD dependant on fence condition.
Up to four zones (two DRUID LCD 20 units, or 1 DRUID LCD 20 and 1 DRUID D2x energizer, or two DRUID D2x energizers) can be controlled from a single Druid 4-Zone keypad.
Document revision history Rev 1.0, 12 January 2021 First release. Rev 1.1, 20 January 2022 Key code for fence return voltage display added. Rev 1.2, 10 May 2022 Nemtek Group Outlets updated. Rev 1.3, 22 May 2022 Front page heading changed.