Grounding The Device - D-Link DIS-2650AP Quick Installation Manual

Wireless ac1200 wave 2 industrial indoor access point
Hide thumbs Also See for DIS-2650AP:
Table of Contents

Advertisement

3.
Place
the
mounting
(attached to the device) on the
location where you want to mount it,
and use the brackets as a guide to
mark where to drill the screw holes.
4.
Drill holes on the marks and insert
wall anchors appropriate for the
material of the wall.
5.
Align the device with the wall anchors and
secure it to the wall using appropriate
screws for the wall anchors.
Installing the Device on a DIN Rail
The DIS-2650AP can be mounted on a standard
DIN rail using the included DIN mounting kit.
Use the following instructions to install the
DIS-2650AP on a rail:
1.
Check that the DIN rail is installed properly
using at least two screws on each end.
2.
Fasten the DIN mounting clip to the
rear panel of the device using the
included mounting screws.
Figure 4: Hooking onto the Rail
3.
Position the DIS-2650AP against the
rail, then tilt it upwards and hook the
DIN rail clip on the back of the device
against the rail. Snap the device into
place to complete the installation.
DIS-2650AP Quick Installation Guide
Installing the Device into a Rack
brackets
The DIS-2650AP can be mounted on a
standard rack using the included mounting
plates. To install the device on a rack:
Attach the mounting brackets to the rear
1.
panel of the device using the
provided installation screws.
Figure 5: Installing onto a Rack
2.
Use the provided screws to attach the
two rear mounting plates to the rack.

Grounding the Device

To use the DIS-2650AP safely, it needs to
be grounded. Please complete these
steps before powering on the device.
1.
Remove the grounding screw from
the top of the DIS-2650AP and place
the grounding cable lug ring on top
of the grounding screw opening.
2.
Insert the grounding screw back into
the grounding screw opening and
use a screwdriver to tighten the
grounding
screw,
grounding cable to the DIS-2650AP.
3.
Attach the terminal lug ring at the
other end of the grounding cable to
an appropriate grounding source.
securing
the
3