Panasonic EW3111 Operating Instructions Manual

Panasonic EW3111 Operating Instructions Manual

Upper arm blood pressure monitor

Advertisement

For questions or assistance with your blood pressure
monitor, call us at 1-800-338-0552.
Panasonic Consumer Electronics Company
A Unit of Matsushita Electric Corporation
of America
One Panasonic Way 3D-1
Secaucus, NJ 07094
No.1 EN,SP
(アメリカ)
© 2002 Matsushita Electric Works, Ltd. All Rights Reserved.
Before operating this device, please read these instructions completely and save this
manual for future use.
Antes de usar este dispositivo, lea completamente estas instrucciones y guarde este
manual para utilizarlo como referencia en el futuro.
Printed in China
Upper Arm Blood Pressure Monitor
Monitor de Presión Arterial de Brazo

Operating Instructions

Instrucciones de
funcionamiento
Model No. EW3111
Modelo No. EW3111

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic EW3111

  • Page 1: Operating Instructions

    For questions or assistance with your blood pressure monitor, call us at 1-800-338-0552. Panasonic Consumer Electronics Company A Unit of Matsushita Electric Corporation of America One Panasonic Way 3D-1 Secaucus, NJ 07094 No.1 EN,SP (アメリカ) © 2002 Matsushita Electric Works, Ltd. All Rights Reserved.
  • Page 2: Table Of Contents

    Troubleshooting ... 16 Specifications... 18 Introduction Thank you for purchasing the Panasonic Upper Arm Blood Pressure Monitor EW3111. Designed for easy, one-touch operation, this monitor incorporates Precise Logic™ technology to provide reliable measurements. Measuring your own blood pressure is an important way of monitoring your health.
  • Page 3: Important Instructions Before Use

    Important Instructions Before Use 1. Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history. 2. If you are taking medication, consult with your physician to determine the most appropriate time to measure your blood pressure.
  • Page 4: Precautions To Ensure Safe, Reliable Operation

    Logic™ measurement system that verifies both the height and width of the pulse wave in order to reliably measure blood pressure. By using the Precise Logic™ measurement system, measurement reliability and accuracy have been improved. Panasonic Technology Double Check Measurement System Checks both Pulse Height and Pulse Width...
  • Page 5: Diagram Of Device

    Diagram of device Tube Display Memory / Recall/(Delete All) Button 1 ON/OFF / Start Button Connecting tube Attachment of cuff holder to cuff Slide from below in the direction of the arrow, at the rear of the unit, until a clicking sound is heard.
  • Page 6: Inserting/Replacing Batteries

    • Low temperature conditions can cause battery life to be shortened. CAUTION: Do not throw batteries into a fire. Doing so may result in an accident or explosion. Fitting the Blood Pressure Monitor 1. Attaching the cuff to the upper arm. • Make sure the cuff is wrapped so that it is in contact with the skin.
  • Page 7: Instructions For Correct Measurement Of Blood Pressure

    Instructions for correct measurement of blood pressure Measurement in a sitting position 1. Rest your elbows on a table or other level surface. 2. Make adjustments so that the height of the cuff and heart are at the same level. 3.
  • Page 8: Storing Blood Pressure Readings

    Storing blood pressure readings This monitor has enough memory capacity to store 21 readings for two users. M1 and M2 will flash on the display after a measurement. 1. Press the Memory/Recall Button number if you want your readings to be recorded. Example: Person A is recorded under M1 M / R...
  • Page 9: Storage

    Storage 1. Loosely roll up the cuff and place it in the cuff holder. 2. Put the tube inside the cuff. • Do not wrap the tube around the unit, etc. Excessive straining of the tube can cause malfunctioning. Troubleshooting Display Status before error Pressurization to above...
  • Page 10: Specifications

    485 g (17.1 oz.) not including batteries Specifications are subject to change without notice. Model EW3111 is intended to be used for the oscillometric PRECISE LOGIC™ measurement of systolic and diastolic blood pressure and pulse rate using a pressurized cuff.

This manual is also suitable for:

Ew3111w

Table of Contents