Multitech MultiConnect MTS2SA-T User Manual

Serial-to-serial adapter with ip
Hide thumbs Also See for MultiConnect MTS2SA-T:
Table of Contents

Advertisement

Quick Links

MultiConnect Adapter
Serial-to-Serial Adapter with IP
User Guide

Advertisement

Table of Contents
loading

Summary of Contents for Multitech MultiConnect MTS2SA-T

  • Page 1 MultiConnect Adapter Serial-to-Serial Adapter with IP User Guide...
  • Page 2 Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
  • Page 3: Table Of Contents

    Chapter 9 – Modem (Transparent) Mode ... 81 Introduction... 81 Scenario 1 – MultiConnect IP as a Modem ... 82 Scenario 2 – Serial Tunneling in Transparent Mode... 83 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Table of Contents Table of Contents...
  • Page 4 Scenario 7 – Sending a Mime Encoded Binary Attachment Using Configuration and Interactive Mode151 Scenario 8 – Sending a Mime Encoded Binary Email with Attachment Using Interactive Mode... 152 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Table of Contents...
  • Page 5 Repair Procedures for U.S. and Canadian Customers... 174 Repair Procedures for International Customers (Outside U.S.A. and Canada) ... 174 Repair Procedures for International Distributors ... 175 Replacement Parts ... 175 Index ... 176 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Table of Contents...
  • Page 6: Chapter 1 - Product Description & Specifications

    Remote diagnostics • Remote metering • Security systems • Ticketing machines • Vending/gaming machines • And more….. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 1 – Product Description and Specifications MultiConnect has several means of management and configuration...
  • Page 7: Types Of Adapters Available

    Although input protection circuitry has been incorporated into the devices to minimize the effect of this static buildup, proper precautions should be taken to avoid exposure to electrostatic discharge during handling and mounting. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 1 – Product Description and Specifications Region...
  • Page 8: Specifications

    8.8 cm x 5.3 cm x 6 cm; 96 g Certifications Safety Certifications: EMC Safety Approvals: CE Marked Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 1 – Product Description and Specifications @ 9V DC: Typical 240mA @ 5V DC:...
  • Page 9 Two-year warranty Internet Applications Software Features Functional Features Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 1 – Product Description and Specifications POP3, PPP, SMTP, SNMP, SNMP, TCP, Telnet, TFTP, UDP protocols DHCP Client: Request IP address for Ethernet Interfaces...
  • Page 10: Led Indicators

    Pins for the Serial-to-Serial Adapter when Power Is Supplied Through the RS-232 Pin Description RX Data TX Data Ground Power Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 1 – Product Description and Specifications Pin 5 Pin 9...
  • Page 11: Chapter 2 - Installation

    2. To attach the brackets to the MultiConnect, slide the mounting brackets into the corresponding slots on the back of the MultiConnect chassis. 3. Attach the adapter to the surface with two screws. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 2 – Installation...
  • Page 12: Serial-To-Serial Adapter Installation

    2. Plug one end of the other RS-232 cable into the back of the Serial-to-Serial adapter. Plug the other end into the RS-232 connector on the serial device you want connected to the Internet. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Serial-to-Serial Adapter Front Back shown with External Power Option...
  • Page 13: Connecting The Power

    Plug the AC cord receptacle into the transformer block. Plug the other end into a power outlet. One end of RS-232 Shown Here Plug Power Supply Cable with Transformer into the Back of the Adapter Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 2 – Installation Plug AC Cord into Transformer Block and Outlet...
  • Page 14: Chapter 3 - Managing And Configuring The Multiconnect Adapter

    To leave Command Mode, exit your terminal or Telnet session or type the word Exit at the command prompt. Note: See the Restore command and IP Escape String command. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 3 – Managing and Configuring the MultiConnect Adapter Adapter...
  • Page 15: Chapter 4 - Command Line Interface (Cli)

    All serial-related applications such as dial-in and dial-out are with respect to the serial interface S0. • The PPP interface is the modem interface S1. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) (CLI)
  • Page 16: General Setup Commands

    1. Too few arguments Possible arguments are default-config and session 2. ERROR: Session not opened Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) This command is not supported through serial dial-in All previous configurations will be lost upon invoking this command.
  • Page 17 Default Value Success Error 1. Too few arguments Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Possible argument(s) are modem “(Error: hostp = “configured host“. Error: hostp=“configured IP address“ This command is not supported through Telnet...
  • Page 18 Usage: set date DD/MM/YYYY Type 'set date ?' for more information Error: Date in DD/MM/YYYY format Too few arguments. Possible argument(s) are Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) serial login General Commands –...
  • Page 19 Success Error 1. Too few arguments "Usage: set watchdog <enable/disable> 2. Invalid string "error: set watchdog <enable/disable>" Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) login serial date time Watchdog timer comes into effect only after reboot. Hence, invoking this command calls for a reboot on save.
  • Page 20 Error 1. Too few arguments Too few arguments. Possible argument(s) are: 2. Invalid argument Invalid argument "Invalid string". Valid arguments are Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) serial date statistics...
  • Page 21 Description Displays the system time. Default Value Success Error 1. Too few arguments 2. Invalid argument Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) statistics configuration date serial Valid arguments are: statistics...
  • Page 22 Displays the configured users. Description Default Value Success Error 1. Too few arguments 2. Invalid argument Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) “Too few arguments. Possible argument(s) are: serial configuration date statistics...
  • Page 23: Ip Setup Commands

    1. Too few arguments “Usage: set ip syslogd <enable/disable> Type ‘set ip syslogd ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) “Usage: set ip dns <enable/disable> Type ‘set ip dns ?’ for more information”...
  • Page 24 Error 1. Too few arguments 2. Multiple matches 3. Invalid String Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) “Usage: set ip syslogd-server <ip_addr> Type ‘set ip syslogd-server ?’ for more information”...
  • Page 25 Type ‘set ip telnet inactivity ?’ for more information” 2. Multiple matches 3. Invalid String Type ‘set ip telnet inactivity ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) escape-monitor escape-string...
  • Page 26 Type ‘set ip tftp ?’ for more information” 2. Invalid string error: Invalid string Type ‘set ip tftp ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) inactivity and inactivity-timeout IP Commands – Setup...
  • Page 27: Serial Setup Commands

    1. Too few arguments “Usage: set serial s0/s1 escape-string <string> Type ‘set serial s0/s1 escape-string ?’ for more information” 2. Multiple matches Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) escape-monitor escape-string...
  • Page 28 5. “error: NO CARRIER / NO DIALTONE / NO ANSWER” or any error return code from the modem Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Serial Commands – Setup...
  • Page 29 Type ‘show serial s0 auto-dialin-ipaddress ? for more information” 4. If “set serial s1 auto-dialin-ipaddress 192.168.2.2” is given “error: Command not supported on the modem port s1” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) auto-dialin...
  • Page 30 4. If “set serial s1 auto-dialin-protocol telnet” is given “error: Command not supported on modem port s1” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) [port_num] is optional here. If port_num is not specified, the standard...
  • Page 31 Description Default Value Success Error Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Succeseri Chapter 4 – Command Line Interface (CLI) set serial [s0] auto-dialin trig-mode <char/ dtr/ dtr-char/ none> This mode is applicable only when auto dial-in is enabled on the serial port S0.
  • Page 32 “error: baud-rate range : [300,……] Type ‘set serial s0/s1 baud-rate ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) The port number should be other than standard TCP ports.
  • Page 33 2. Multiple matches 3. Time limit “error: Time limit supported : <1 – 60 secs> Type ‘set serial s0/s1 buffer-time ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) buffer-datasize buffer-time...
  • Page 34 “error: Data-bits range supported: [7/8] Type ‘set serial s0/s1 data-bits ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Use double quotes if more than one word is used in the Modem port (S1) will always have connect-type as modem since it is a Serial Commands –...
  • Page 35 "Usage: set serial s0/s1 modem dial-number <phone-num> Type 'set serial s0/s1 modem dial-number ?' for more information" Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Telnet Auto-Dialout and PPP cannot be enabled when this mode is The configured modem strings takes precedence over the Serial Commands –...
  • Page 36 "Usage: set serial s0/s1 modem dialing-method <configuration/chat- script> Type 'set serial s0/s1 modem dialing-method ?' for more information" Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) The configured modem strings takes precedence over the MODEM.CNF...
  • Page 37 1. Too few arguments "Usage: set serial s0/s1 modem hangup-string <hang-str> Type 'set serial s0/s1 modem hangup-string ?' for more information" Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) • "linkup s1" command is issued •...
  • Page 38 2. Invalid parity setting “error: parity supported: [even/odd/none] Type ‘set serial s0/s1 parity ?’ for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Set serial s0 modem init-string 1 ATZ Set serial s0 modem init-string 1 "ATZ AT&F"...
  • Page 39 4. If ‘set serial s1 raw-dialout <enable/disable>’ is given “error: Command not supported on modem port s1” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) This is applicable only if the "set serial s0 auto-dialin trig-mode" is...
  • Page 40 Displays the modem-related configuration for serial port S0 or S1. Default Value Success Error 1. Too few arguments Possible value(s) are Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) statistics modem-configuration configuration chat-script...
  • Page 41 Description Default Value Success Error 1. Too few arguments Possible value(s) are Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) • Status (If serial is used by any application) • Rx Bytes •...
  • Page 42: Ppp Setup Commands

    Success Error 1. Too few arguments 2. Invalid string Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Too few argument(s). Possible argument(s) are: chap, pap, and pap-chap Invalid argument. Valid argument(s) are...
  • Page 43 1. Too few arguments Possible argument(s) are client-only and client-or-lan 2. Invalid string Invalid argument. Valid argument(s) are client-only and client-or-lan Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) PPP Commands – Setup...
  • Page 44 Sets the user name that the remote peer will use for authentication. Description Ipmodule Default Value Success Error 1. Too few arguments Possible value(s) are valid user name Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Invalid argument PPP Commands – Setup...
  • Page 45 Up / Down 1. Too few arguments Error Possible argument(s) are 2. Invalid argument Invalid argument Valid argument(s) are Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) configuration ip-addr statistics link-status configuration...
  • Page 46 Default Value Success Error 1. Too few arguments Possible argument(s) are 2. Invalid argument Invalid argument Valid argument(s) are: Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) configuration ip-addr statistics link-status configuration ip-addr...
  • Page 47: Http Server Commands

    1. Too few arguments 2. Invalid string Type 'set device P<n> ?' for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) “Usage: set ip http-page <default/serial> “Usage: set "ip http <enable/disable>...
  • Page 48 Success Error 1. Too few arguments “ERROR: Too few arguments Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Type 'show device-parameter ?' for more information” HTTP Server Commands – Setup HTTP Server Commands – Show...
  • Page 49: Smtp Client Commands

    Error 1. Too few arguments “Usage: set send-mail from-address <email-address> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) Type 'set send-mail from-address-identity ?' for more information” Type 'set send-mail from-address ?' for more information”...
  • Page 50 NULL Default Value orte d : [ 1 to ]e Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) SMTP Client Commands – Setup where n = 1 to 5. where n = 1 to 5.
  • Page 51 1. Too few arguments “Usage: show send-mail configuration Type 'show send-mail ?' for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) SMTP Client Commands – Setup [-t <email-address1, email-address2, ...>] [-c <email-address1, email-address2, ...>]...
  • Page 52: Pop3 Client Commands

    Type 'set recv-mail mailbox-password ?' for more information 2. Invalid string Type 'set recv-mail mailbox-password ?' for more information Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) POP3 Client Commands – Setup...
  • Page 53 “recv-mail quit” command is executed. Default Value Success Error 1. Too few arguments Usage: recv-mail delete <index> Type 'recv-mail ?' for more information Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) POP3 Client Commands – Setup...
  • Page 54 Displays the recv-mail related configuration. Description Default Value Success Error 1. Too few arguments Possible value(s) are configuration Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) POP3 Client Commands – Setup POP3 Client Commands – Show...
  • Page 55: Ftp Client Commands

    3. When invoked from Command shell connected through This command is not supported through Telnet Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) IP-address FTP Client Commands – Setup...
  • Page 56 Description NULL Default Value Success Error 1. Too few arguments Possible value(s) are configured. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) FTP Client Commands – Setup FTP Client Commands – Show...
  • Page 57: Sntp Client Commands

    "error: Invalid Offset" 2. Too few arguments “Usage: set sntp-client time-zone-offset <+/-hh:mm> Type set sntp-client time-zone-offset ? for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) SNTP Client Commands – Setup...
  • Page 58 2. Too few arguments “Usage: set sntp-client daylight-saving start-ordinal <string> Type set sntp-client daylight-saving start-ordinal ? for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) SNTP Client Commands – Setup...
  • Page 59 2. Too few arguments “Usage: set sntp-client daylight-saving end-ordinal <string> Type set sntp-client daylight-saving end-ordinal ? for more information” Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) SNTP Client Commands – Setup...
  • Page 60 Success Error 1. Too few arguments Possible value(s) are configuration Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 4 – Command Line Interface (CLI) hh = 00 to 23 mm = 00 to 59 SNTP Client Commands – Setup...
  • Page 61: Chapter 5 - Setting Country Or Region Codes Using The Cli

    Greece Hong Kong Hungary Iceland Indonesia Ireland Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 5 – Setting Country or Region Codes Using the CLI There is no validation on the country code value. statistics country-code configuration chat-script...
  • Page 62: Chapter 6 - Prerequisite Configurations

    1. S0 - Device Port - RS-232 port connects to the Host/Serial device. 2. S1 - Modem Port - RJ-11 phone jack port dials the Service Provider, obtains an IP Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 6 – Prerequisite Configurations Address, and provides the IP ability to reach the Host/Serial devices connected over the device port.
  • Page 63 The figure below depicts the two modes of operation. The modes can be configured through the Command Line Interface (CLI). By default the MultiConnect IP is set to operate in the IP Mode. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 6 – Prerequisite Configurations...
  • Page 64 Command to terminate the physical link: # hangup [serial-interface] Notes: Example: Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 6 – Prerequisite Configurations • This command is valid only for modem port S1 and is invalid for device port S0.
  • Page 65: Chapter 7 - Telnet Dialout

    Set the Auto dialout protocol for the serial port S0. # set serial s0 auto-dialout-protocol telnet An ERROR message displays if any of the above details are not configured or are not valid. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout...
  • Page 66 # set serial s1 data-bits <7/8> • Set the Stop bits for the serial port S1 to be taken for a PPP session # set serial s1 stop-bits <1/1.5/2> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout...
  • Page 67: Scenario 1 - Manual Dialout

    You can switch from Command Prompt to Dialout session using the restore session command. • You can switch from Dialout session to Command Prompt using <escape-monitor-string>. Manual Dialout Feature Through the Command Shell Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout...
  • Page 68 The serial port is opened with the current serial configuration. When escape-monitor is enabled, care should be taken during file transfer that the escape- monitor-string is not part of the data. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout Optional Configuration...
  • Page 69: Scenario 2 - Auto Dialout

    Once the session is opened successfully, there can be two-way traffic between the Telnet session and the remote serial device. Auto Dialout Feature in Telnet Mode Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout Optional Configuration...
  • Page 70 When a dialout session authentication is enabled as specified in the optional commands, the session prompts for a user name and password before opening the session successfully. (Enabled by default). The serial port is opened with the current serial configuration. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout...
  • Page 71: Scenario 3 - Auto Dialout In Raw Mode

    Important You cannot switch between the Command Prompt and the Dialout session in RAW-mode. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Auto Dialout Feature in RAW Mode Chapter 7 – Telnet Dialout Optional Configuration...
  • Page 72 Commands, the session prompts for a user name and password before opening the session successfully. The serial port is opened with the current serial configuration. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 7 – Telnet Dialout Optional Configuration...
  • Page 73: Chapter 8 - Auto Dial-In Feature

    Enable/Disable the RAW mode globally for all Auto-Dial-in sessions. # set ip telnet raw-mode <enable/disable> • Enable/Disable the RAW mode for Auto-Dial-in session on serial port S0. # set serial s0 raw-dial-in <enable/disable> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 8 – Auto Dial-in Feature...
  • Page 74: Scenario 1 - Manual Serial Dial-In

    You can switch from Command Prompt to Dial-in session using the restore session command. • You can switch from Dial-in session to Command Prompt using <escape-monitor-string>. Manual Dial-in Feature through the Command Shell Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 8 – Auto Dial-in Feature...
  • Page 75 The dial-in session is closed when the Telnet session is closed. • When escape-monitor is enabled, care should be taken during file transfer that the escape- monitor-string is not part of the data. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 8 – Auto Dial-in Feature...
  • Page 76: Scenario 2 - Serial Auto Dial-In In Telnet Mode

    RAW mode (Global and each port) MUST BE DISABLED using the following command: Enable/Disable the RAW mode globally for all Auto-Dial-in sessions: # set ip telnet raw-mode <enable/disable> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Auto Dial-in Feature in Telnet Mode Chapter 8 – Auto Dial-in Feature...
  • Page 77 The Dial-in session is closed when the configuration session is closed (if opened). When escape-monitor is enabled, care should be taken during file transfer that the escape- monitor-string is not part of the data. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 8 – Auto Dial-in Feature...
  • Page 78: Scenario 3 - Auto Dial-In Session In Raw Mode

    (Refer to Chapter 6 - Prerequisite Configurations - Physical Link Established over the Modem Port) # set ppp ppp0 ipcp-mode client-only # set ppp ppp0 username "MultiConnect" # set ppp ppp0 password "MultiConnect" # save Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 8 – Auto Dial-in Feature...
  • Page 79: Scenario 4 - Serial Tunneling Mode

    Device-2) using two MultiConnect IP modules, which are located apart geographically. Once the PPP link is up with an IP address on S1, the dial-in session can occur. The Serial Devices then communicate to each other across the MultiConnect IP modules. Serial Tunneling Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 80 # set ppp ppp0 username "MultiConnect" # set ppp ppp0 password "MultiConnect" # set ppp ppp0 local-ip-addr 202.54.39.96 mask 255.255.255.255 # set ppp ppp0 remote-ip-addr 202.54.39.95 mask 255.255.255.255 # save Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 8 – Auto Dial-in Feature...
  • Page 81: Chapter 9 - Modem (Transparent) Mode

    # set serial s0 escape-monitor enable • Set the Escape-Monitor-String to switch between Data mode and Command mode # set serial s0 escape-string "+++inets0" Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 9 – Modem (Transparent) Mode Mode...
  • Page 82: Scenario 1 - Multiconnect Ip As A Modem

    Chapter 9 – Modem (Transparent) Mode Scenario 1 – MultiConnect IP as a Modem In this scenario, once the physical link is up on the built-in modem interface; i.e., by dialing or answering, Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 83: Scenario 2 - Serial Tunneling In Transparent Mode

    RS-232 interface (S0) of the MultiConnect IP modules. Serial tunneling is achieved in the transparent mode where raw data is communicated. Serial Tunneling in Transparent Mode Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 84 You can switch from Command mode to Data mode using the restore session command. • The data session is dropped if the physical link goes down. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 9 – Modem (Transparent) Mode...
  • Page 85: Chapter 10 - Modem Mode At Commands, S-Registers, Result Codes

    First, the commands that begin with letters are listed in alphabetical order • Then the commands that begin with symbols are listed in this order &, \, –, %, +, #, +++ • Fast Connect Commands • V.92 Commands Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 86: Command Types

    Select Pulse Dial Make/Break Ratio &V Display Current Configuration and Stored Profiles &V1 Display Last Connection Statistics Single Line Connect Message Enable Report Line Signal Level Report Line Signal Quality -STE Set Telephony Extension Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 87: Call Control Commands

    Transmit Break to Remote Break Control MNP Extended Services Data Compression Commands Data Compression Data Compression Reporting Enable/Disable Data Compression V.8/V.8bis Commands +A8E V.8 and V.8bis Operation Controls +A8I CI Signal Indication Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 88: Command Detail

    The 'gate' digit (tone dialing only). Some countries may prohibit sending of these digits during dialing (tone dialing only) Redial last number. (Must be placed immediately after ATD .) Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) ) key to execute most commands. ETURN...
  • Page 89 If on-hook, the modem will go off-hook and enter command mode. For US models, the modem will remain off-hook. For global models, the modem will return on-hook after a period of time determined by S7. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 90 Renegotiate rate without speed change (used for diagnostic purpose only. Renegotiate rate down one speed (used for diagnostic purpose only). (Not in V.22bis) Renegotiate rate up one speed (used for diagnostic purpose only). (Not in V.22bis) Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 91 W1 Upon connection, the modem reports the modulation, line speed, the error correction protocol, and the DTE speed, respectively. Subsequent responses are disabled. W2 Upon connection, the modem reports the DCE speed (e.g., CONNECT 14400). Subsequent responses are disabled. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 92 &D2 - DTR drop causes the modem to hang up. Auto-answer is inhibited. (Default.) &D3 - DTR drop causes the modem to perform a soft reset as if the Z command were received. The &Y setting determines which profile is loaded. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 93 Selects how the modem will control DSR. The parameter value, if valid, is written to S21 bit 6. &S0 DSR is always high (ON). &S1 DSR goes high (ON) only during a connection. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 94 B1 E1 L1 M1 N0 QO T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 S00:000 S02:043 S06:002 S07:050 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000 S36:007 S40:168 S41:195 S46:138 S95:000 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 95 0, 1 Default: None Description: This command selects which user profile will be used after a hard reset. &Y0 The modem will use profile 0. &Y1 The modem will use profile 1. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 96 Same as \K0 . Send break immediately to the remote modem. Same as \K2 . Send break to the remote modem in sequence with the transmitted data. Same as \K4 . Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 97 Protocol = Line Speed = Asymmetric rates display as /rate:TX/rate:RX; e.g., /1200 TX/75 RX. Voice and Data = Blank for Data mode only. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) “K56” for K56flex modulation. “V34” for V.34 modulation.
  • Page 98 NOT in use, the modem will go off-hook after a short pause, then respond with CONNECT or NO CARRIER message. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) options. The bit field are defined as follows:...
  • Page 99 Speeds attempted during fallback/fall forward are those shown to be available in the rate sequences exchanged during the initial connection. Fallback/fall forward is available in error correction and normal modes, but not in direct mode or synchronous mode with external clocks. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 100 Reporting Current or Selected Values Command: +A8E? Reporting Supported Range of Parameter Values Command: +A8E=? Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Enable DCE-controlled V.8 origination negotiation without +A8x indications. Enable DCE-controlled V.8 origination negotiation with +A8x indications.
  • Page 101 Reporting Current or Selected Values Command: +DS? Reporting Supported Range of Parameter Values Command: +DS=? Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Specifies the desired direction(s) of operation of the data compression function from the DTE point of view. +DS0 Negotiated;...
  • Page 102 (if any), before the final result code (e.g., CONNECT) is transmitted. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) signaled to remote DCE. Decimal number 0 specifying that any transmitted V.42 L-SIGNAL will...
  • Page 103 Command: +ESR? Reporting Supported Range of Parameter Values: Command: +ESR=? Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Decimal number which specifies the initial requested mode of operation when the modem is operating as the originator. The options are: Initiate call with Direct Mode.
  • Page 104 Revision Identification Request (Not available in V.22bis) Description: Displays the modem version, revision level, or date. This is the same as the I3 command. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) buffered transmit data will be discarded when the local DTE requests call disconnection.
  • Page 105 <rate> Specifies the DTE-modem interface operation rate in bits/s. The available rates Reporting Current or Selected Values Command: Reporting Supported Range of Parameter Values Command: Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) < > modem_by_DTE S pecifies the method to be used by the DTE to control None XON/XOFF on transmitted data (XON/XOFF on transmit data);...
  • Page 106 Report Syntax +MCR Response: +MCR: <carrier> <carrier> Alphanumeric code corresponding to the reported carrier. Defined values are: Report Syntax +MRR Response: +MRR: <tx_rate>,<rx_rate> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) B103 For Bell 103 B212 For Bell 212 For V.21...
  • Page 107 Command: Reporting Supported Range of Parameter Values Command: Result Code: OK - Valid subparameter string Otherwise ERROR Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) <carrier> Possible (<min_rx_rate>, <min_rx_rate>, (<min_tx_rate>), and <max_tx_rate>) Rates (bps) B103 B212 1200 Rx/75 Tx or 75 Rx/1200 Tx...
  • Page 108 +VRID1 Reports Caller ID with unformatted presentation to the DTE. Report Commands: +VRID? Reports the Mode Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) the data items in a <Tag><Value> pair format. The expected pairs are date, time, name, and caller code (telephone number).
  • Page 109 If V.80 methods are used, each response line shall be a separate extended in-band message. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Left angle bracket (less than sign) (3Ch) token Unique 32-bit hexadecimal...
  • Page 110 Data Calling signal detected (e.g., V.25 CT, V.8 CI) Fax Answering signal detected (e.g., T.30 CED, DIS) Fax Calling signal detected (e.g., T.30 CNG) V.8bis signal detected Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Definition Diagnostic Command Specification revision number, digit.digit Call Setup Result code...
  • Page 111 Value Description None V.42bis and V.44 MNP5™ Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Definition INFO0 bit 20; 0 INFOc bits 79-88 INFOc bits 26-29 or 35-38 or 44- 47 or 53-56- or 62-65 or 71-74 INFOa bits 26-29 MP bit 50;...
  • Page 112 ProtocolViolation n400exceeded LAPM retransmission Count Timer NegotiationFailed DisconnectFrameReceived SabmeFrameReceived LossOfSynchronization Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Notes Call setup issues Not in V.58 Not in V.58 Not in V.58, only if modem can detect it Same as value 2A, CallAttemptsLimitExceeded...
  • Page 113 DTE and sending of the OK result code to the DTE is controlled by the S12 register. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description This is version 0.9 Data Answer signal detected;...
  • Page 114: Fastconnect Commands

    V.22 and V.22 bis FastConnect protocols. Specifies the initial requested mode of operation when the modem is operating as the originator. The options are: Defined Values: Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Normal connection (Default) FastConnect without answer tone Reserved...
  • Page 115: Commands (+P And -Q Commands)

    +PMHR13 Result Codes: OK 0-13 in V.92 Mode (+MS=V92) ERROR Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Request modem-on-hold if enabled by +PMH and collect caller ID information if enabled by +VRID. Toggle V.24 circuit 125. (Default.) Hang-up.
  • Page 116 OK 0, 1, or 3 in V.92 Mode (+MS=V.92) ERROR Report Commands: +PQC? +PQC=? Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Deny V.92 modem-on-hold Request (Default.) Grant MOH with 10-second timeout Grant MOH with 20-second timeout Grant MOH with 30-second timeout...
  • Page 117 Report Commands: -QCPS? -QCPS=? Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) The modems decide whether or not to use the short startup procedures. The short startup procedures can only be used if enabled by the +PQC command. (Default.) Reserved.
  • Page 118: S-Registers

    0–127 10 (^J) decimal 0–255 8 (^H) Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) value.. Description Number of Rings to Auto-Answer: Sets the number of rings until the modem answers. ATS0=0 disables autoanswer completely. * Ring Counter. Counts the rings that have occurred. S1 is cleared if no rings occur over eight-second intervals.
  • Page 119: Register Unit Range Default Description

    0.001 s 50–255 0.02 s 0–255 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description Wait Time Before Blind Dialing or for Dial Tone. 1. Sets the length of time, in seconds, that the modem will wait before starting to dial after going off-hook when blind dialing. This operation, however, may be affected by some ATX options according to country restrictions.
  • Page 120 Range Default 138 (8Ah) General Bit-Mapped Options Status. Indicates the status of S19 and S20 52 (34h) Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description command options. Bit 0 This bit is ignored. Bit 1 Command echo (En) Disabled (E0) Enabled (E1) (Default.)
  • Page 121 117 (75h) Speaker/Results Bit-Mapped Options Status. Indicates the status seconds 0–255 0.01 s 0–255 0.01 s 0–255 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description of command options. Default: 117 (75h) (01110101b) Bits 0-1 Speaker volume (Ln) Off (L0) Low (L1) (Default.)
  • Page 122 73 (49Ah) General Bit-Mapped Options Status. Indicates the status of 10 ms 0–255 10 s 0–255 192 (C0h) General Bit-Mapped Options Status. Indicates bit mapped options Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description command options. Default: 73 (49h) (01001001b) Bit 2 Leased line control (&Ln) Dial up line (&L0) (Default.)
  • Page 123 Default (V.22bis only) seconds 0–255 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description LAPM Failure Control. This value indicates what should happen upon a LAPM failure. These fallback options are initiated immediately upon connection if S48=128. If an invalid number is entered, the number is accepted into the register, but S36 will act as if the default value has been entered.
  • Page 124 Chapter 10 − Modem Mode AT Commands, S-Registers, and Result Codes Register Unit Range Default 104 (68h) General Bit-Mapped Options Status. Indicates the status of Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description command options. Default: 104 (68h) (01101000b)
  • Page 125 3, 7, or 128 128 (V.22bis only) 0–26 0–15 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description Break Handling Options Break Signals provide a way for the user to get the attention of the remote modem. The break type depends on the speed application.
  • Page 126 13 (0Dh) * Register value may be stored on one of two user profiles with the &W command in all except V.22bis. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Description Extended Result Codes Control. A bit set to a 1 in this parameter, in conjunction with the W command, will enable the corresponding extended result code.
  • Page 127: Result Codes

    Description Form +F4 * +FCERROR Fax data speed. High speed fax data (V.27, V.29, V.33, or V.17) is expected but a V.21 signan6 lcegn Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 0 OK) V.90 Terminology Carrier Compression Protocol...
  • Page 128 26400 bps; carrier reporting is enabled. (See S95, Xn.) 58 * +MRR: 28800 Connected at 28800 bps and carrier reporting enabled. Modem connects to the line at 28800 bps; carrier reporting is enabled. (See S95, Xn.) Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 129 Connected at 34000 bps. Modem connects to the line at 34000 bps and carrier reporting is enabled.(See S95, Xn.) 152 * +MRR: 36000 Connected at 36000 bps. Modem connects to the line at 36000 bps and carrier reporting is enabled.(See S95, Xn.) Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 130 Connected at 37333 bps. Modem connects to the line at 37333 bps and DCE SPEED 37333 reporting is enabled. 186 * CONNECT Connected at 38667 bps. Modem connects to the line at 38667 bps and DCE SPEED 38667 reporting is enabled. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 131 Connected at 54667 bps. The modem has connected to the line at 54667 bps and carrier reporting is enabled. (See S95, Xn) Note: An asterisk (*) in the Short Form column means that this Result Code is not active in V.22bis modems. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 132: Chapter 11 - Point-To-Point Protocol

    Upon successful execution of this command, the MultiConnect IP will return an OK or an error message. Command: # user add <username> [password] Example: # user add user1 user1 (Or) # user add user1 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 11 – Point-to-Point Protocol...
  • Page 133: Setting Passwords

    Enabling/Disabling compression • Configure the compression algorithm Serial Interface Related Parameters • Configure the Connect Type • Configure the modem settings • Configure the dialing trigger mode Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 11 – Point-to-Point Protocol...
  • Page 134: Ppp Interface Related Parameters

    This command allows you to view the PPP link IP address Command: # show ppp [interface] ip-addr Example: #show ppp ppp0 ip-addr local: 192.168.2.1 remote: 192.168.2.2 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 11 – Point-to-Point Protocol...
  • Page 135: Serial Interface Related Parameters

    When the dialing-trig-mode is configured as command, the serial command: device can control the physical link establishment and link termination with the aid of the commands linkup s1 and hangup s1 respectively. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 11 – Point-to-Point Protocol...
  • Page 136: Chapter 12 - Http Server

    This application is applicable only in the MultiConnect IP's non-transparent mode. • This application can be used only after the PPP link is UP with an IP Address on the modem port. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 12 – HTTP Server...
  • Page 137: Setup And Configuration

    The http-s0.HTML Web page can be replaced by the OEM's Home Page specific to the product. More details regarding design conventions, procedure for uploading, and hosting this page are explained later in this chapter. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Index.htm (Default Index Page) Chapter 12 – HTTP Server...
  • Page 138: Configuration Modes

    Minimum = If the Type is integer, corresponds to Minimum value. If the Type is String, corresponds to Minimum no of characters. Maximum = If the Type Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 12 – HTTP Server...
  • Page 139 The serial device parameter list file (http-host-param) for the demo Web page, which is included with the default setup, (see Figure 3) uses the following parameters and values: P0:UPSstatus:S:0:5:ON P1:Efficiency:I:0:100:90 P2:NoiseLevel:I:0:100:5 P3:OverloadCapacity:I:0:100:89 P4:Tolerance:I:0:100:90 P5:InputCurrent:I:0:100:78 P6:InputLineVoltage:I:0:100:90 P7:OutputVoltage:I:0:100:45 P8:BatteryVoltage:I:0:100:78 P9:Load:S:0:100:90 P10:Alarm:S:0:10:silence Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 12 – HTTP Server...
  • Page 140: The Embedded Html Page

    The Parameter tags <P1, P2, …> should be contained in the parameter list. The URL for Host Configuration http-s0.HTML when the host device's HTML page is uploaded to the MultiConnect IP. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) MUST be a shell script. Description...
  • Page 141: Uploading The Web Page And Parameter List

    192.168.2.92 (IP-Address of the MultiConnect IP) tftp>verbose tftp>binary tftp>trace tftp>put http-host-param tftp>put http-s0.HTML. • Upload all the files using the similar command. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 12 – HTTP Server...
  • Page 142: Monitoring And Configuring The Host Through A Browser

    /cgi-bin/post-query path in the ACTION field of your HTML file. The rest is set by the Post- Query script. Serial Device Parameter Updating Process The serial device probes/polls the MultiConnect IP for newly configured parameter values from the browser. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 12 – HTTP Server...
  • Page 143: Chapter 13 - Smtp Client

    (Refer to Chapter 6 Prerequisite Configurations - Physical Link Established over the Modem Port for more details) • In the event of PPP link DOWN, the SMTP request triggers PPP link establishment. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client command prompt. interactive...
  • Page 144: Setup And Configuration Prerequisites

    Set reply-to address of maximum length 64 characters. By default the server takes the from address as the reply-to-address. • If this is configured, this address is taken as the reply to address. set send-mail reply-to-address <email-ID> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 145: Scenario 1 - Sending A Text Email From The Command Prompt

    3. If the subject option is not specified and is not pre-configured using set commands, SMNP enters into interactive mode and requests a subject to be entered. 4. Type Ctrl+C to quit the email at any given time. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 146: Scenario 2 - Sending A Text Email From The Interactive Mode

    3. If the subject option is not specified and is not pre-configured using set command, SNMP enters into interactive mode and requests a subject to be entered. 4. Type Ctrl+C to quit the email at any given time. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 147: Scenario 3 - Sending A Text Email Using Configuration And Interactive Mode

    3. If the subject option is not specified or is not pre-configured using set commands, SNMP enters into interactive mode and requests a subject to be entered. 4. Type Ctrl+C to quit the email at any given time. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 148: Scenario 4 - Sending A Text Email Using No Configuration

    2. If the subject is already configured using set command, it will be taken as the subject for the email. 3. Type Ctrl+C to quit the email at any given time. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 149: Scenario 5 - Sending A Mime Encoded Binary Attachment Using Command Prompt

    5. If the host wants to quit the email while sending the binary attachment body, type Ctrl+C and wait for 3 seconds without entering any character to quit the email. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 150: Scenario 6 - Sending A Mime Encoded Binary Attachment Using The Command Prompt

    If the host wants to quit the email while sending the binary attachment body, type Ctrl+C and wait for 3 seconds without entering any character to quit the email. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 151: Interactive Mode

    5. If the host wants to quit the email while sending the binary attachment body, type Ctrl+C and wait for 3 seconds without entering any character. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 152: Scenario 8 - Sending A Mime Encoded Binary Email With Attachment Using Interactive Mode

    Notes: 1. The email is sent only to addresses entered in interactive mode. 2. If the subject is pre-configured using set com80.5 -1.159(eit willbe eusd a)s23 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 13 – SMTP Client...
  • Page 153: Chapter 14 - Pop3 Client

    MultiConnect IP to retrieve emails. set recv-mail server-name 192.168.2.10 set recv-mail server-port 110 set recv-mail mailbox-name mtss set recv-mail mailbox-password mtsspass Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 14 – POP3 Client...
  • Page 154: Optional Configuration For Deleting Emails From The Server

    If leave mail on server is disabled, then an email retrieved from the POP3 server using the commands recv-mail mail or recv-mail mail <n>, where n is the message number, is deleted from the POP3 server. The default value is enable. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 14 – POP3 Client...
  • Page 155: Scenario 1 - Retrieving Emails

    Scenario 2 – Retrieving the Number of Emails and the Total Email Size Use the command recv-mail stat to retrieve the number of emails and the total email size in octets. The output is single line. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 156: Scenario 3 - Retrieving The Email List

    Use the command recv-mail header to retrieve the message header of all emails. The output is multi- lined. Use the command recv-mail header <n> to retrieve the message header of the nth email. The output is multi-lined. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
  • Page 157: Scenario 5 - Retrieving First T Lines

    Use this command to retrieve the unique email ID of a message. The unique message ID is used to identify the message with a unique string. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 14 – POP3 Client...
  • Page 158: Error Messages

    This error occurs if the POP3 client could not authenticate to the POP3 server. This could happen when the username or password is not valid. • Other errors Other errors might occur due to timeout, none availability of resources, etc. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 14 – POP3 Client...
  • Page 159: Scenario 8 - Sending A Mime Encoded Binary Email Using Interactive Mode

    If the host wants to quit the email while sending the binary attachment body, type Ctrl+C and wait for 3 seconds without entering any character to quit the email. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 14 – POP3 Client...
  • Page 160: Chapter 15 - Ftp Client

    The file transfer can be done only if the server supports BINARY/IMAGE data type. The file can be received only if the server supports SIZE command. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client...
  • Page 161: Prerequisites

    If the above mandatory fields are not configured or if the configured device and the server specified in the command line are different, MultiConnect IP prompts the user to enter login name and password. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client...
  • Page 162: Scenario 1 - Listing Directory Contents

    ‘ASCII’ to receive the list of contents of the directory. Configuration None ftp -l -p ip-address Command Result Response OK: FTP session closed Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client...
  • Page 163: Scenario 3 - Listing Directory Contents

    If the '-p' option is specified in the command, the data connection will be in passive mode set ftp machine <ip-address/host-name> login <user-name> Configuration ftp -l [-p] ip-address Command Result Response OK: FTP session closed Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client...
  • Page 164: Scenario 5 - Sending A File To The Ftp Server

    If the '-p' option is specified in the command, the data connection will be in passive mode Configuration set ftp machine <ip-address/host-name> login <user-name> password <passwd> account <passwd> Command ftp -t [-p] ip-address OK: FTP session closed Result Response Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client password.
  • Page 165: Scenario 7 - Sending A File To The Ftp Server

    Note: If the '-p' option is specified in the command, the data connection will be in passive mode None Configuration ftp -r [-p] ip-address Command OK: FTP session closed Result Response Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) name. Chapter 15 – FTP Client...
  • Page 166: Scenario 9 - Receiving A File From The Ftp Server

    Note: If the '-p' option is specified in the command, the data connection will be in passive mode set ftp machine <ip-address/host-name> login <user-name> password <passwd> Configuration account <passwd> Command ftp -r [-p] ip-address OK: FTP session closed Result Response Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client...
  • Page 167: Scenario 10 - Receiving A File From The Ftp Server

    The serial device has to read and store the data received. It has to implement timeout mechanisms to come out in cases where the network is prone to errors. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 15 – FTP Client...
  • Page 168: Chapter 16 - Sntp Client

    # set sntp-client polling-time <300> ERROR Message The send-mail command prompts for the ERROR message if any of the above details are not configured or not valid. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 16 – SNTP Client...
  • Page 169 Set the End Month for Daylight Savings. # set sntp-client daylight-saving end-month <october> • Set the End Time for Daylight Savings. # set sntp-client daylight-saving end-time <10:00> Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 16 – SNTP Client Savings.
  • Page 170: Scenario 1 - Updating Time From The Ntp Server

    When the server cannot be reach or is not running, the SNTP client tries to reach the server every 10 seconds for 6 times and waits for the polling time, and then it tries again to reach the server as before. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Chapter 16 – SNTP Client...
  • Page 171: Appendix A - Flash Upgrade

    If your operating system does not include a TFTP client program, a TFTP client program is available for Windows users from the Internet. Walusoft's TFTP Suite Pro is recommended. The URL is: http://www.walusoft.co.uk/download.htm Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Appendix A – Flash Upgrade...
  • Page 172: Prerequisite 2 - Serial Port Configuration

    Perform a file upload. The MultiConnect Adapter reboots and will be up after a few seconds (10-15 secs). The MultiConnect Adapter reboots after it has been successfully upgraded. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Appendix A – Flash Upgrade...
  • Page 173: Appendix B - Regulatory Information

    Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits. Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Information Appendix B – Regulatory Information...
  • Page 174: Appendix C - Warranty And Service

    Multi-Tech Warranty Statement Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of purchase is not provided, two, five, or ten years (depending on model) from date of shipment.
  • Page 175: Repair Procedures For International Distributors

    Multi-Tech products. You can place an order with SupplyNet via mail, phone, fax or the Internet at the following addresses: Mail: SupplyNet, Inc. 614 Corporate Way Valley Cottage, NY 10989 Phone: 800 826-0279 Fax: 914 267-2420 Email: info@thesupplynet.com Internet: http://www.thesupplynet.com Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Appendix C – Warranty and Service...
  • Page 176: Index

    +GMM ...104 +GMR ...104 +IFC ...105 +ILRR ...105 +IPR ...105 +MCR...106 ...106 +MRR...106 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Index ... 107 +PCW ... 115 ...102 +PIG ... 116 +PMH ... 115 +PMHF ... 116 +PMHR... 115 +PMHT...
  • Page 177 Extended Result Codes and Call Progress Information command X ...92 Extended Result Codes Control S95 ...126 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) FastConnect control command file naming conventions file size constraints... 140 Fixed DTE Rate command +IPR...
  • Page 178 ...40 show serial modem configuration...40 show serial modem country code ...41, 61 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) show serial statistics... 41 IP Setup Commands set IP DNS client set IP host name set IP syslogd...
  • Page 179 Restore Factory Configuration command &F Restore session IP command ...16 Result Code Form command V...91 Result codes...127 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) ...156 Result Codes ... 85 Retrieved Caller (CID) Report command +VRID Return Online to Data Mode command ...155 Revision Identification Request command +GMR ...157...
  • Page 180 Set watchdog IP command...19 Setup Auto Dial-out in RAW-Mode Commands Show build run file IP command ...20 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) Show configuration IP command ...23 Show date IP Show HTTP configuration IP command Show HTTP device parameter IP command ...49...
  • Page 181 ...124 ...118 ...119 ...119 ...119 ...125 ...125 ...119 Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) S91... 125 S95... 126 Store Current Configuration Settings command &W Store Telephone Numbers command &Zy=x Telnet dialout feature ... 65 Telnet IP command ...

This manual is also suitable for:

Multiconnect mts2sa-t-r

Table of Contents