Casio fx-570ES PLUS User Manual page 7

Casio calculator user's guide
Hide thumbs Also See for fx-570ES PLUS:
Table of Contents

Advertisement

Linear Display (LineIO) causes fractions and
other expressions to be displayed in a single
line.
Note: • The calculator switches to Linear Display automatically whenever
you enter the STAT, BASE-N, MATRIX, or VECTOR Mode. • In this manual,
the
symbol next to a sample operation indicates Natural Display, while
the
symbol indicates Linear Display.
Deg
Rad
unit for value input and calculation result display.
Note: In this manual, the
degrees, while the
Fix
Sci
calculation result.
Fix: The value you specify (from 0 to 9) controls the number of decimal
places for displayed calculation results. Calculation results are rounded off
to the specified digit before being displayed.
Example:
Sci: The value you specify (from 1 to 10) controls the number of significant
digits for displayed calculation results. Calculation results are rounded off to
the specified digit before being displayed.
Example:
Norm: Selecting one of the two available settings (Norm 1, Norm 2)
determines the range in which results will be displayed in non-exponential
format. Outside the specified range, results are displayed using exponential
format.
Norm 1: 10
–2
Example:
ab/c
fraction (d/c) for display of fractions in calculation results.
CMPLX
a
bi
(
+
) or polar coordinates (
STAT
(frequency) column in the STAT Mode Stat Editor.
Disp
a comma for the calculation result decimal point. A dot is always displayed
during input.
Note: When dot is selected as the decimal point, the separator for multiple
results is a comma (,). When comma is selected, the separator is a
semicolon (;).
CONT
Contrast" for details.
Gra
Specifies degrees, radians or grads as the angle
symbol indicates radians.
Norm
Specifies the number of digits for display of a
100 ÷ 7 = 14.286 (Fix 3)
14.29
1 ÷ 7 = 1.4286
1.429
x
x
|
|, |
|
10
10
1 ÷ 200 = 5
0.005
d/c
Specifies either mixed fraction (ab/c) or improper
i
a+b
;
r θ Specifies either rectangular coordinates
r
ON ;
OFF
Dot ;
Comma
Adjusts display contrast. See "Adjusting Display
symbol next to a sample operation indicates
(Fix 2)
–1
10
(Sci 5)
–1
10
(Sci 4)
Norm 2: 10
–9
–3
10
(Norm 1)
(Norm 2)
θ) for EQN Mode solutions.
Specifies whether or not to display a FREQ
Specifies whether to display a dot or
E-6
x
x
|
|, |
|
10
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-991es plus

Table of Contents