Download Print this page

Zenith ZLI012100 User Manual page 2

Lithium batteries

Advertisement

PRE-INSTALLATION
Before proceeding with the battery installation, it
is necessary to check the compatibility between the
battery and the application it will be used.
What to check before installation:
Read the battery data sheet again.
Check the maximum absorption of your load and
compare with the electrical characteristics of the battery
(see technical data sheet).
Verify that the size, weight and length of the battery
cables are compatible with your application.
Check that the temperatures of the environment
in where the battery will be installed is within the limits
indicated in the technical data sheet.
INSTALLATION / USE
The battery has two cables, one red (positive) and a
black one (negative), with which it will be possible to
load and unload it also.
The battery is supplied without connector, available
only on request.
Use a connector with adequate capacity for the
application.
During installation, make sure that the battery is off.
Respect the polarities (red +, black -).
Use cables with a suitable section for the application,
if necessary, ask the manufacturer.
The favourite mounting position is the spontaneous
one with handles on top. For any different positions
ask for manufacturer's authorization.
Secure the battery in case of movement or
vibration. Use the appropiate threaded inserts (1)
provided on the container.
1.Threaded inserts
2.ON/OFF
Dimostrative example of ZLI012100 battery data sheet
Corrente costante di scarica / Constant discharge current
Corrente impulsiva di scarica / Impulse discharge current
Corrente impulsiva di carica / Impulse charge current
Tensione di carica consigliata / Recommended charging voltage
Tensione di carica massima / Maximum charging voltage
Dimostrative example of ZLI012100 battery data sheet
Temperatura di carica massima / Maximum charge temperature
During use:
It is strongly recommended that you turn on the
battery first and then the load.
Connect/disconnect only when the battery is not
used (no flashing led).
The battery has an ON/OFF button (2) for
switching the BMS on and off (in OFF there is no
no voltage on the poles).
Five LEDs (3) indicate the level of charge (S.o.C.) and
the battery status.
A connectors (4) to plug: the specific display (6) to
view all the battery parameters (RS485).
A selector (5), usable only with the special display,
necessary when connecting several batteries (max 4)
in parallel.
For more detailed information contact the
manufacturer.
3.S.o.C. indicators
4.RS485
Corrente max di carica consigliata
Max recommended charging current
Temperatura di scarica massima
Maximum discharge temperature
Temperatura di scarica consigliata
Recommended discharge temperature
Temperatura di carica consigliata
Recommended charge temperature
5.Selector (Dip-Switch)
200A
Max 250A per 15"
Max 400A per 3"
100A
> 150A per 10''
13.9V
14.6V
-15°C / +60°C
-10°C / +45°C
0°C / +60°C
+5°C / +40°C
6.Display
2

Advertisement

loading