Snap the orifice stem back in place in this position in-
5.
serting it into the indent in the conversion cap
Insert the hexagon cap back into the regulator and
6.
tighten, do not over-tighten.
IMPORTANT: Attach the metallic sticker included with
7.
the LP conversion kit to the bottom of the appliance as
shown. This sticker provides notice that the appliance
has been converted for use with LP gas. It should be lo-
cated near the appliance rating plate.
→  "Rating plate location", Page 16
Note: If you change the type of gas back to natural gas
at a later point, remove the sticker.
5.2 Replacing the orifices
Remove all burner grates, burner caps and burner
1.
bases.
Remove the natural gas orifices and replace them with
2.
LP orifices using a 7 mm socket wrench. See burner
chart →  Page 16 .
For ease of installation use a small piece of tape and
insert it in the socket wrench to prevent the orifice
from falling out.
It is important to make sure that the orifices do not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
Normal burner with one orifice
Fasten the orifices.
3.
Save the orifices removed from the appliance for future
4.
use.
5.3 Adjusting the gas valves
⁠ .
Turn the control knobs to position off.
1.
Pull off the control knobs.
2.
Remove the screws at each burner and lift off the main
3.
top from the cooktop.
Remove the switch from the valve.
4.
Adjust the bypass jet on each valve with a flat blade
5.
screwdriver, with a small thin blade. Refer to the burner
chart for the correct setting of the setting screws (M).
→  "Burner chart", Page 16
Use setting
tightened properly.
Use setting
loosened until the gas flow from the burner is correct.
Turn ¼ turn to the left from LP setting.
Replace the switch on the valves.
6.
Conversion to LP gas en-us
for LP Gas. The bypass jet must be
for natural gas. The bypass jet must be