Section 1 Description
Type
Item
Ambient light intensity
Insulation resistance
Dielectric strength voltage
Degree of protection
Vibration resistance
Shock resistance
Cable (optional) *3
Materials
Weight
*Packaged
Accessories
Applicable standard
Please note that the operation may differ from conventional ON/OFF switching because of the safety circuit.
*1.
*2. Flashing after a lapse of 30000 hours as an indicator of preventive maintenance.
When extending the cable(100 m max), be sure to use a cable with at least same performance. Be sure to
*3.
route the F3SN-B cable separated from high-potential power lines or through an exclusive conduit.
Test rod is not supplied with the F3SN-B
*4.
The intermediate mounting bracket is supplied with the following types:
*5.
Types which have the total length of the light curtain from 640 mm to 1280 mm: 1 set for each of emitter and
receiver
Types which have the total length of the light curtain over 1280 mm: 2 sets for each of emitter and receiver

1-3-2 Response time

The response time of OSSD outputs are as follows:
F3SN-B
P25
F3SN-B
P25
F3SN-B
P25
Response time of F3SP-B1P is 10 ms, operation time is 100 ms.
If the controller is included in the set, calculate safety distance by adding the controller response
[Note]:
time to the F3SN response time.
B-6
F3SN-B
P25
Incandescent lamp : 3,000 Ix max. (light intensity on the receiver surface)
Sunlight
: 10,000 Ix max. (light intensity on the receiver surface)
20 MΩ min. (at 500 VDC)
1000 VAC 50/60 Hz 1 minute
IP65(IEC60529)
Normal operation : 10 to 55 Hz, double amplitude 0.7 mm, X, Y and Z directions 20 sweeps
Normal operation : 100 m/s
UL20276 (flame-resistant:), 8 cores (0.3 mm
with braided wire shield, allowable bending radius: R36 mm
Case
: Aluminum
Cap
: Zinc die-cast
Optical cover
: PMMA (acrylic resin)
Cable
: Oil-proof PVC
Calculate with the following equation:
Weight of light curtain with protective height of 180 mm to 738 mm (g)
Weight of light curtain with protective height of 747 mm to 1402 mm (g)
Weight of light curtain with protective height of 1417 mm to 1822 mm (g)
Test rod *4, Instruction manual, Mounting brackets (top and bottom),
Mounting brackets (intermediate)*5, Error mode label
IEC61496-1, EN61496-1 TYPE 2 ESPE (Electro-Sensitive Protective Equipment)
IEC61496-2 TYPE 2 AOPD (Active Opto-electronic Protective Devices)
Protective
height(mm)
217 to 772
787 to 1297
1312 to 1822
217 to 757
787 to 1297
1327 to 1807
277 to 757
817 to 1297
1357 to 1777
F3SN-B
P40
2
, X,Y and Z directions 1000 times
2
x 4pairs), external diameter 6.6 mm,
= (Protective height + 100) x 2 + 1300)
= (Protective height + 100) x 2 + 1700)
= (Protective height + 100) x 2 + 2100)
P70.
No. of beams
Response time
(ON to OFF)
13 to 50
51 to 85
86 to 120
7 to 25
26 to 43
44 to 60
5 to 13
14 to 22
23 to 30
F3SN-B
P70
Response time
(OFF to ON)
10.0
40
12.5
50
15.0
60
10.0
40
12.5
50
15.0
60
10.0
40
12.5
50
15.0
60