LG LS090CP(AS-C0914DH0) Svc Manual page 22

Lg room air conditioner svc manual(exploded view)
Table of Contents

Advertisement

Installation
Connecting the pipings to the indoor unit
and drain hose to drain pipe.
• Put a couple drops of refrigerant oil on the face
of the flare before assembling taking care not to
add any contaminants.
• Align the center of the pipings and sufficiently
tighten the flare nut by hand.
Indoor unit tubing
• Tighten the flare nut with a wrench.
Connection pipe
Flare nut
Spanner (fixed)
Outside diameter
mm
inch
Ø6.35
1/4
Ø9.52
3/8
Ø12.7
1/2
Ø15.88
5/8
• Mount the clamp on the boss with a type "B"
screw.(SE-H/P: 9k, 12k C/O: 12k)
Type "B" screw
Clamp
Boss
• When extending the drain hose at the indoor
unit, install the drain pipe.
Drain pipe
Vinyl tape(narrow)
Adhesive
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Flare nut
Pipings
Indoor unit tubing
Torque wrench
Torque
1.8
4.2
5.5
6.6
Drain hose
Indoor unit drain hose
Wrap the insulation material around the
connecting portion.
• Overlap the connection pipe insulation material
and the indoor unit pipe insulation material. Bind
them together with vinyl tape so that there is no
gap.
Plastic bands Insulation material
• Wrap the area which accommodates the rear piping
housing section with vinyl tape.
Connection
pipe
Vinyl tape
(wide)
Connecting cable
Vinyl tape(narrow)
• Bundle the piping and drain hose together by
wrapping them with vinyl tape over the range
within which they fit into the rear piping housing
section.
Wrap with vinyl tape
Pipe
Drain hose
For right rear piping
Route the indoor tubing and the drain
hose to the required piping hole position.
- 22 -
Indoor
unit pipe
Wrap with vinyl tape
Pipe
Vinyl tape(wide)
Drain hose
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents